6.4 Driver Parameters (All types)

370

6.4 Driver Parameters (All types)

No.

Parameter name

Default

value

(reference)

Input range

Unit

Remarks

1 Type (upper)

(Manufacturing information)

Space

2 Type (middle)

(Manufacturing information)

Space

3 Type (lower)

(Manufacturing information)

Space

4 Manufacturing data

(Manufacturing information)

Space

5 Manufacturing data

(Manufacturing information)

Space

6 Manufacturing data

(Manufacturing information)

Space

7 Manufacturing data

(Manufacturing information)

Space

8 Board type

(Function information)

31

0 to 255

9 Installation type word 1

(Function information)

0101H

0000H to FFFFH

Bits 0 to 7:

Current detection circuit

type for first axis on

board

Bits 8 to 15: Current detection circuit

type for second axis on

board

0: 0 W (Not installed)

1: 20 to 30 W

2: 50 to 300 W

3: 400 to 750 W

4: 600 to 800 W (Maximum

300% output) (only for 1-axis

type PCB)

5: 1000W (for 50A linear type)

(only for 1-axis type PCB)

10 Installation type word 2

(Function information)

0000H

0000H to FFFFH

Bits 0 to 15: Reserved.

11 (Function information)

0000H

0000H to FFFFH

12 Software version

(Function information)

0000H

0000H to FFFFH

Version No.×100

13 Maximum supported motor ID

number (Function information)

0000H

0000H to FFFFH

Motors whose motor identification

number is between 0 and the value of

this parameter are supported.

14 Motor control data use selection

(Function information)

0000H

0000H to FFFFH

Bits 0 to 3: Select if using motor control

data

0: Use motor control related

data in driver flash ROM

1: Use motor control constant

table data transferred from

main

15 (Function information)

0000H

0000H to FFFFH

16 (Function information)

0000H

0000H to FFFFH

17 (Function information)

0000H

0000H to FFFFH

18 (Function information)

0000H

0000H to FFFFH

19 (Function information)

0000H

0000H to FFFFH

20 (Function information)

0000H

0000H to FFFFH

21 (Function information)

0000H

0000H to FFFFH

22 (Function information)

0000H

0000H to FFFFH

23 (Configuration information)

0000H

0000H to FFFFH

24

Constructed Capacity (Motor

Rated Output) (compatible with

E, priority on E) (Configuration

information)

003CH

0000H to FFFFH

W

(* Data for other models)

25

Constructed Voltage (Motor

Voltage) (compatible with E,

priority on E) (Configuration

information)

00C8H

0000H to FFFFH

V

Highest bit is AC/DC classification bit

(OFF: AC, ON: DC)

(* Data for other models)