Chapter 7

Troubleshooting

7.3 Error List (MAIN application)

453

In the panel window, the error numbers follow E in the display.

Error

No.

Error name

Description, action, etc.

C70 Absolute coordinate

non-confirmation error

Absolute coordinates have not been confirmed. The power

must be reconnected.

This error may also occur if operation is performed

immediately after changing an encoder parameter,

performing an absolute encoder reset or resetting an

encoder error, without first executing a software reset or

reconnecting the power.

C71 Synchro slave-axis command error A command was issued to the synchro slave axis.
C72 Overrun error

The overrun sensor was actuated.

C73 Target-locus soft limit over error

The target position or movement locus exceeds a soft limit.

* In the case of a SCARA specification, position data may

not exist for the applicable axis.

C74 Actual-position soft limit over error The actual position exceeds a soft limit by the “soft

limit/actual position margin” or more.

C75 Motion-data-packet generation

logic error

The motion-data-packet generation logic is invalid.

C76 Movement-position count over

error

Too many packets are generated simultaneously.

C77 Handling-packet overflow error

The servo handling packets overflowed.

C78 Motion-data-packet overflow error The servo motion data packets overflowed.
C79 Pole sense operation error

Operation is disabled in the pole sense mode.

C7A Servo unsupported function error

An attempt was made to use an unsupported function.

C7B Odd-pulse slide error

Internal servo calculation error

C7C Odd-pulse processing logic error

Internal servo calculation error

C7D Packet pulse shortage error

Internal servo calculation error

C7E Quadratic equation solution error

An error was detected while calculating a quadratic

equation solution.

C7F No valid specified axis error

No valid axes are specified.

C80 Servo-packet calculation logic error Internal servo calculation error

If the controller is of absolute-encoder specification and an

“Error No. C74, Actual-position soft limit over error” is also

present, an absolute reset may not have been executed

correctly and consequently a servo packet calculation

overflow occurred due to a current position error.

If this is the case, perform an absolute reset again by

following the procedure specified in the operation manual.

(Performing an “encoder error reset” operation in the

absolute reset window alone does not allow the controller

to recognize the current position correctly.

Always perform an absolute reset by strictly following the

specified procedure.)

C81 Operation-amount logic during

servo ON

Servo processing logic error

C82 Servo direct command type error

Servo processing logic error

C83 Servo calculation method type

error

The servo calculation method type is invalid.

C84 In-use axis servo OFF error

The servo of an axis currently in use (being processed)

was turned off.

C85 Non-installed driver error

Driver is not installed for the applicable axis.

C86 Driver servo ready OFF error

The ready signal for the driver of the applicable axis is

OFF.

C87 SEL unsupported function error

An attempt was made to use a function not supported by

SEL.

O

pe

ra

tio

n-

ca

nc

el

la

tio

n

le

ve

l e

rro

rs

C88 Speed specification error

The specified speed is invalid.