3 menu tree, Menu tree -6, Operation – Yokogawa EJX440A User Manual

Page 16

Advertising
background image

<3. Operation>

3-6

IM 01C25T01-01E

3.3 Menu Tree

1 Device setup

2 Pres

3 AO

4 LRV

5 URV

1 Process variables

2 Diag/Service

3 Basic setup

4 Detailed setup

5. Review

1 Pres

2 Pres %

3 AO

4 SP

5 SP %

6 Snsr temp

7 Engr Disp

8 Engr exp

9 Engr Unit

1 Status group 1

2 Status group 2

3 Status group 3

4 Status group 4

5 Status group 5

6 Status group 6

7 Status group 7

8 Status group 8

9 Status group 9

1 Keypad input

2 Apply values
1 D/A trim

2 Scaled D/A trim

3 Clear D/A trim
1 Pres Zero trim

2 Pres trim

3 P LTP

4 P UTP

5 Pres trim info.

1 Pres

2 Pres %

3 SP

4 Snsr temp

1 Pres

2 Pres %

3 Unit

4 Pres sensor trim
1 SP

2 SP %

3 SP Unit

4 A/G Select

5 SP H/L Select

6 SP sensor trim
7 SP setup

1 Pres

2 Pres %

3 AO

4 SP

5 SP %

6 Snsr temp

7 Engr Disp

8 Engr exp

9 Engr Unit

Digital Output

1 Loop test

2 D/A trim

3 Scaled D/A trim

4 Clear D/A trim

5 AO alm typ

6 Auto recover

7 AO lower limit

8 AO upper limit

1 Poll addr

2 Num req preams

3 Burst mode

4 Burst option

1 Pres Alert mode

2 Config Pres Alerts

3 SP Alart mode

4 Config SP Alerts

5 Temp Alert mode

6 Config Temp Alerts

7 DO Config

1 Disp Out 1

2 Disp Out 2

3 Disp Out 3

4 Disp Out 4

1 Universal rev

2 Fld dev rev

3 Software rev

1 S.C.

2 Num of points

3 Point setting

1 P LTD

2 P UTD

3 Clear P snsr trim

1 SP LTD

2 SP UTD

3 Clear SP snsr trim

1 Disp Pres % fnctn

2 Disp Pres % Reso

3 Pres disp point
1 Engr LRV

2 Engr URV

3 Engr exp

4 Engr Unit

5 Engr point

6 Set Engr Unit

7 Modify Engr Unit

1 Keypad input

2 Apply values

1 Date

2 Descriptor

3 Message

4 Write Protect

1 Static Pres trim

2 SP LTP

3 SP UTP

4 SP trim info.
1 Trim Who

2 Trim Date

3 Trim Loc

4 Trim Desc

1 Digital Output

2 DO Select

3 DO Signal type

4 DO Test

1 Pres Zero trim

2 Pres trim

3 P LTP

4 P UTP

5 Pres trim info.

1 Static Pres trim

2 SP LTP

3 SP UTP

4 SP trim info.

1 T.Z. Cmp mode

2 Temp Zero

1 SP Range

2 SP Unit

3 SP Damp

4 SP A/G Setup

5 SP H/L Select

1 Tag

2 Date

3 Descriptor

4 Message

5 Model 1

6 Model 2

7 Model 3

8 Write Protect

9 Ext SW

Revision #s

Additional Info

1 Status

2 Self test

1 Re-range

2 Analog output trim

3 Pres sensor trim

4 SP sensor trim

5 Trim info.

1 Error log view

2 Error log Clear

1 Process variables

2 Re-range

3 Unit

4 Xfer fnctn

5 Pres Damp

6 Low cut

7 Low cut mode

8 H/L Swap

9 Bi-dir mode

Quick resp

T.Z. Cmp menu

S.C. menu

1 Process variables

2 Analog output

3 HART output

4 Process Alerts
1 Disp select

2 P disp condition

3 SP disp condition

4 Engr disp range

5 Bar Indicator

1 Field device info

2 Sensor information

3 Self test

1 Pressure sensor

2 SP sensor

3 Temp sensor

1 Keypad input

2 Apply values

1 Linear

2 Sq root

Linear

Zero
Normal

Reverse

1 Snsr temp

2 Amp temp

3 Temp Unit

1 Test device

2 Loop test

3 Calibration

4 Diag Parameters

5 Error log

Online Menu

(Device setup)

(Process variables)

(Diag/Service)

1 Tag

2 Unit

3 Re-range

4 Device information

5 Xfer fnctn
6 Pres Damp
7 Low cut
8 Low cut mode
9 H/L Swap

SP setup

(Basic setup)

1 Sensors

2 Signal condition

3 Output condition

4 Display condition

5 Device information

6 Test Key

(Detailed setup)

1 Keypad Input

2 Wrt protect menu

Hot Key

1 LRV

2 URV

3 Unit

4 LSL

5 USL

6 Min Span

1 Write protect

2 Enable wrt 10min

3 New password

4 Software seal

F0307-1.ai

See

A

(next page).

Advertising
This manual is related to the following products: