Operation – Yokogawa EJX440A User Manual

Page 31

Advertising
background image

<3. Operation>

3-21

IM 01C25T01-01E

1

F0334-1.ai

Select the

Scaled D/A trim item.

EJX:YOKOGAWA

Analog output trim

1 D/A trim

2 Scaled D/A trim

3 Clear D/A trim

HELP

SET

HOME

OK

EJX:YOKOGAWA

WARN-Loop should be

removed from

automatic control

DEL

SET

ABORT

OK

2

Press

OK (F4).

EJX:YOKOGAWA

Trim will be scaled

from 4.000 to 20.000

1 Proceed

2 Change

HELP

DEL

ABORT ENTER

3

Select

Change, and press

ENTER (F4).

When item 3.

Proceed is

selected,

D/A trim must be

carried out.

EJX:YOKOGAWA

Set scale- Lo output

value

4.000000

1

HELP

ABORT

4

Enter the value read on the meter

when the signal is 4 mA. In this

case, Enter the value of the

voltage across a 250Ω resistor

(1 V), and press

ENTER (F4).

DEL

ENTER

(OK)

(ENTER)

‘1’

EJX:YOKOGAWA

Set scale- Hi output

value

20.000000

5

HELP

ABORT

5

Enter the value read on the meter

when the signal is 20 mA. Then,

enter

5, and press ENTER (F4).

DEL

ENTER

(ENTER)

‘5’

Example 2: To adjust using a voltmeter

6

Select

Proceed and press

ENTER (F4).

EJX:YOKOGAWA

Trim will be scaled

from 1.000 to 5.000

1 Proceed

2 Change

HELP

SET

ABORT ENTER

EJX:YOKOGAWA

Connect reference

meter

DEL

SET

ABORT

OK

7

Connect the voltmeter, and press

OK (F4).

(OK)

(ENTER)

1. Device setup
2 Diag/Service
3. Calibration
2. Analog output trim
2. Scaled D/A trim

F0334-2.ai

EJX:YOKOGAWA

Enter meter value

1.000000

1.010

HELP

ABORT

9

9

8

Enter the reading of the voltmeter

(1.010), and press

ENTER (F4).

(The output of the transmitter

changes.)

DEL

ENTER

(ENTER)

(ENTER)

‘1 . 0 1’

EJX:YOKOGAWA

Scaled output: 1.000

equal readout

device?

1 Yes

2 No

HELP

ABORT

10

DEL

ENTER

Voltmeter reading: 1.010

If the reading on the voltmeter is

1.000, select

Yes and press

ENTER (F4).

If the reading is not 1.000, select

No. Repeat steps and until

the voltmeter reads 1.000 V.

Voltmeter reading: 1.000

11

Press

OK (F4). A 100% output

signal is output.

EJX:YOKOGAWA

Setting fld dev

output to 20mA

HELP

SET

ABORT

OK

EJX:YOKOGAWA

Enter meter value

5.000000

5.210

HELP

DEL

ABORT ENTER

12

EJX:YOKOGAWA

Scaled output: 5.000

equal readout

device?

1 Yes

2 No

HELP

DEL

ABORT ENTER

13

EJX:YOKOGAWA

NOTE-Loop may be

returned to automatic

control

HELP

ABORT

14

Enter the reading of the voltmeter

(5.210), and press

ENTER (F4).

DEL

OK

(ENTER)

“Returning fid dev to

original output”

(OK)

(ENTER)

‘5 . 2 1’

(OK)

Voltmeter reading: 5.210

Select

Yes and press ENTER

(F4).

Press

OK (F4).

Voltmeter reading: 5.000

EJX:YOKOGAWA

Setting fld dev

output to 4mA

HELP

DEL

ABORT

OK

8

Press

OK (F4). A 0% output

signal is output.

(OK)

Advertising