8 model and suffix code – Yokogawa Integral Oxygen Analyzer ZR202 User Manual

Page 26

Advertising
background image

IM 11M13A01-04E

2-8

Model and Suffix code

ZR202S

-A
-B
-C
-E
-F
-G
-K
-L
-M
-P
-R
-S
-W

-A
-B
-C
-D

-S
-C

ATEX certified flameproof (*11)
FM certified explosionproof
CSA certified explosionproof
IECEx certified flameproof (*12)

T05.EPS

-E

-R
-T

-M
-T

-A

-E

Auto Calibration

-N
-A
-B

Integrated type Explosionproof Zirconia Oxygen Analyzer

Model

Suffix code

Option

code

Description

Length

Wetted material

SUS316
Stainless steel with Inconel calibration gas tube

(*7)

Flange
(*1)

Reference air

Gas Thread

Connection box thread

Instruction manual

Options

-040
-070
-100
-150
-200

0.4 m
0.7 m
1.0 m
1.5 m
2.0 m

Explosion
proof
Approval

/C
/CV
/SV
/H
/SCT
/PT

Inconel bolt

(*2)

Check valve

(*3)

Stop valve (*3)
Hood

(*6)

Stainless steel tag plate

(*4)

Printed tag plate

(*4)

*1 The thickness of the flange depends on its dimensions.
*2 Inconel probe bolts and U shape pipe are used. Use this option for high temperature use (ranging from 600 to700

ЊC).

*3 Specify either /CV or /SV option code. Please select /CV or /SV.

*4

Specify either /SCT or /PT option code.

*5 No need to specify the option codes, /CV and /SV, since the check valves are provided with the autocalibration unit.
*6 Sun shield hood is still effective even if scratched. Hood is necessary for outdoor installation out of sun shield roof.
*7 Recommended if measured gas contains corrosive gas like chlorine.
*8 Piping for reference air must be installed to supply reference air constantly at a specified flow rate.
*9

When selecting code -B (FM certified explosionproof) or -C (CSA certified explosionproof), select code -T(1/2 NPT).

*10 Confirm inside diameter of pipe attached to customer’s flange in case that -A or -E is selected.
*11 Certified cable glands that meet or exceed the requirements for EEx d IIB+H

2

IP66, provide at least 6 threads engaged when installed,

and resist heat so that they can be used in the operating environment, should be used.
*12 Certified cable glands that meet or exceed the requirements for Ex d IIB+H

2

T2, Ex tD A21 IP66 T300

ЊC

, provide at least 6 threads engaged

when installed, and resist heat so that they can be used in the operating environment, should be used.

Rc 1/4
1/4 NPT(F)

M20x1.5 mm
1/2 NPT (*9)

Not required
Horizontal mounting (*5)
Vertical mounting (*5)

External connection (Instrument air) (*8)

English

Always -A

ANSI Class 150 2 RF SUS304 (*10)
ANSI Class 150 3 RF SUS304
ANSI Class 150 4 RF SUS304
DIN PN10 DN50 A SUS304 (*10)
DIN PN10 DN80 A SUS304
DIN PN10 DN100 A SUS304
JIS 5K 65 FF SUS304
JIS 10K 65 FF SUS304
JIS 10K 80 FF SUS304
JIS 10K 100 FF SUS304
JPI Class 150 4 RF SUS304
JPI Class 150 3 RF SUS304
Westinghouse