<5. Display and Operations while Connected to GC1000 Mark II>

5-6

IM 11B06C01-01E

n

Operation Status Display Bar

The Operation Status Display bar is a tool for monitoring the current operation status of the

analyzer and for operating it.

l

Window elements

F5-2-3.ai

Measurement status

e

d

c

b

a

Measurement status change queued

Method

a: Status (change command) buttons

“Process” status

“Manual” status

“Lab” status

b: Operation Mode (change command) buttons

“Run” mode

“Pause” mode

“Stop” mode

“Cancel Command

(dedicated for commanding)

c: Measurement Status Change specifying buttons

“Stream Sequence”

“Stream (Continuous)”

“Stream (Once)”

“Calibration (Verification)”

“Start Calibration (Verification)”

“End Calibration (Verification)”

“Cancel Setting”

“Calibration (Verification) Method”

d: Change Range command button

e: Help Display button

l

Button functions and display information

The following table lists the button/display functions and display information.

Button/Display

Function and Display Information

Status (change

command) buttons

These buttons display the current analyzer status. They also enable you

to conduct status change by clicking the status button that you want to

change.

Operation Mode

(change command)

buttons

These buttons display the current analyzer operation mode and the status

in which operation mode change has been commanded and reserved.

They also enable you to change the command mode by clicking the

operation mode button that you want to change. The “Cancel Command”

button is used to cancel queued operation mode changes.

Measurement Status

Change setting buttons

These are setting dedicated buttons used to specify measurement status

by clicking the button of the measurement status you wish to change to.

The “Start Calibration (Verification)” and “End Calibration (Verification)”

buttons are used to start/end calibration (verification) manually. The “Cancel

Setting” button is used to cancel queued measurement status changes. The

“Calibration (Verification) Method” button is used to change the calibration

(verification) method.

Range Change

command button

Commands a range change.

If a database-related setting change is made on the analyzer unit side, a

message appears, disabling command issuance. This button requires user

level B.

Help Display button

Displays the Help mode of the Analyzer Operation window.

Measurement status

Indicates the current measurement status.

Measurement status

change queued

When a measurement status change has been made, this box indicates

the currently specified measurement status until the measurement status

changes to the specified one.

Method

Indicates the current method number.

HELP !

To operate the Operation Status Display bar, user level “B” or “C” is required.

SEE ALSO

For how to change the user level, see section 3.4.