<Appendix B List of Messages>

B-2

IM 11B06C01-01E

n

Overview Window

Message

Meaning

Countermeasures

R

un

ni

ng

AS

ET

Engineering Terminal is

already running.

An attempt was made to run the

multiple ASET.

An ASET is run on a PC.

It is necessary to close

Analysis results. Please close

and restart Analysis Results.

An attempt was made to run a

ASET during running Analysis

Results Window.

Re-run ASET after closing

Analysis Results Window.

[C

on

ne

ct

]

Other PC connect with the

analyzer.

A PC can not run ASET because

4 sets of PC has already

communicated with a PCAS.

Execute the connection command

from ASET after closing a ASET

which communicate with PCAS.

Cannot open communication

device.

The communication can not be

started dues to the problem of a

communication device.

Check the operation status of

Ethernet card and TCP/IP setting.

[F

or

ce

d

C

on

ne

ct

] Password is incorrect. Forced

connection is not possible.

The password entered at Forced

connection is invalid.

Enter the valid password.

O

n

co

m

m

un

ic

at

io

n

The communication has

disconnected between the

Analyzer and PCAS.

The communication has

disconnected between the

Analyzer and PCAS.

Check the cable between PCAS

and the Analyzers, and execute

the conncetion command from

ASET again.

Periodic communication has

disconnected between the

Analyzer and PCAS.

PCAS failed to receive the

periodic communication from a

analyzer connected.

Check the cable between PCAS

and the Analyzers, and execute

the conncetion command from

ASET again.

Other PC starts the forced

communication. ASET (XXX.

XXX.XXX.XXX)

A PC which IP address

XX.XXX.XXX.XXX has cut

the communication by Forced

connection.

Execute “connect” command after

closing ASET connected to PCAS.

PCAS(XXX.XXX.XXX.XXX)

requests to disconnect the

communication.

The communication is

disconnected by a forced

connection from a PC which has

IP address XXX.XXX.XXX.XXX.

Execute “connect” command

from ASET after checking

communication status of PCAS.

[O

pe

ra

tio

n

M

od

e]

Password is invalid. Please

try again.

Password entered is invalid.

Enter the valid password.

[D

is

pl

ay

Se

tti

ng

] A maximum of 16 ID’s is

allowed.¥nIf you add another

ID, you must delete ID in

advance.

An attempt is being made to

register 17th analyzer on the

overview window.

Max. analyzers entered is 16. It is

needed to delete one analyzer if

the other one is added.

se

rv

er

s

el

ec

t d

ia

lo

g]

This IP Address is incorrect.

Invalid IP address is entered.

Enter the valid IP address.

This IP address overlaps with

Server XXX.

The IP address entered is same

as one of a Server XXX.

The IP address which has already

registered can not be set. Specify

the other IP address.

The server ID is out of range.

The server ID which can not be

used has been entered. The

available server ID is from 241 to

254.

Specify the server ID from 241 to

254.

[T

ra

ns

fe

r

Pa

ra

m

et

er

s]

File operation is available in

only Process/Lab - Stop.

An attempt was made to upload/

download the setting parameter

except Process/Lab -Stop mode.

The upload/download of the

setting parameter is available on

Process/Lab - Stop mode.

The selected file is not a

parameter file.

An attempt is being made to

download the file which is not for

the setting parameter.

Select the correct parameter file.

[R

es

et

An

al

yz

er

] Analyzer reset is available in

only Process/Lab - Stop.

An attempt is being made to

command “Reset Analyzer” except

Process/Lab - Stop mode.

“Reset Analyzer” command is

available on only Process/Lab

- Stop mode.