3 switching window display, 4 saving and reading data, Switching window display -45 – Yokogawa GC8000 Process Gas Chromatograph User Manual

Page 155: Saving and reading data -45, Nfile calibration coefficient history window, See also, Nwindow menu

Advertising
background image

<5. Display and Operations while Connected to GC1000 Mark II>

5-45

IM 11B06C01-01E

n

File Calibration Coefficient History Window

The File Calibration Coefficient History window is a window in which data of the Calibration

Coefficient History window that has been saved to a file is recalled for reference. (You cannot

recall other analysis results acquisition windows.)
The contents displayed in the window are identical to those of the Calibration Coefficient History

window.

SEE ALSO

• Calibration Coefficient History Window for the display contents

Calibration Coefficient History Window for the display contents

5.4.3

Switching Window Display

In the analysis results window, only one window can be displayed at a time. If you wish to

display another window, switch the current window to the desired one. Note that only a graph

window that has been produced in a history window (Concentration Analysis History, Calibration

coefficient History, Retention Time History, File Concentration Analysis History, or File Retention

Time History or File Calibration coefficient History) can be displayed simultaneously with the

history window, or the data source of the graph window.

TIP

Display of a graph window

• A graph window, produced by executing the Create command in the Graph menu while a history window is

being displayed, is displayed concurrently with the history window, or the data source of the graph window.

If the history window is switched to another, the graph window that was displayed in the same frame will

also be hidden accordingly. However, when the history window concerned is re-displayed, the graph

window is also brought back to display.

n

Window Menu

The Window menu is used to switch to a window to display. Choosing the window name you wish

to display in this menu allows that window to appear.
Note that the currently displayed window(s) has a checkmark ( ) added to the front of its name

in the menu.

5.4.4

Saving and Reading Data

Data of the analysis results acquisition windows (Latest Analysis Results, Concentration Analysis

History, Retention Time History, Laboratory Analysis Results and Calibration coefficient History)

are updated each time an analysis is completed. If these data are saved to a file, data up to when

it was saved can be freely referred to later by recalling it in the relevant file reference window (File

Analysis Results, File Concentration Analysis History, File Retention Time History, File Laboratory

Analysis Results or File Calibration coefficient History).

5th Edition : Nov. 16, 2011-00

Advertising