(HNTRLib2) (/var/opt/hitachi/HNTRLib2/spool/hntr2n.log (n indicates a

file number)).

If a lot of integrated trace information is output, the older information might

end up getting deleted in a very short amount of time. Also, if a large amount

of integrated trace information is suddenly all output at the same time, any

integrated trace information that is overflowing the buffer might not be saved

into the integrated trace files. To save as much information as possible,

change the settings for Hitachi Network Objectplaza Trace Library to increase

the integrated trace file size and buffer size. Note that if the values are too

large, it will place a heavy load on the system. When determining these

values, be sure to consider these operational tradeoffs.

The following table shows the default and recommended values for the

integrated trace file settings.

Table 3-32 Default and recommended values for the integrated trace file

settings

Setting

Default value

Recommended

value

Integrated trace file size

256 (kilobytes)

4096 (kilobytes)

Number of integrated trace files

4

8

Buffer size per

monitoring

interval

Monitoring interval

10 (seconds)

5 (seconds)

Buffer size

64 (kilobytes)

256 (kilobytes)

Number of

messages to be

output per

monitoring

interval

Monitoring interval

0 (seconds)

0 (seconds)

Number of messages

to be output

0 (transactions)

0 (transactions)

If Hitachi Network Objectplaza Trace Library (HNTRLib2) is already installed,

the existing settings will be inherited. If you change these settings, keep in

mind that programs other than HDLM also use them. If an earlier Hitachi

Network Objectplaza Trace Library (HNTRLib) is already installed, the settings

will not be inherited.

Notes on Using the Hitachi Network Objectplaza Trace Library

Note the following when using Hitachi Network Objectplaza trace library:

If HNTRLib has already been installed when you install HDLM, the settings

in the trace library will not be inherited by HNTRLib2. HDLM uses the

HNTRLib2 default settings.

If HNTRLib2 has already been installed on a host when you install HDLM,

the settings in the trace library will be inherited.

If a different Hitachi product is using HNTRLib2 when you attempt to

remove HDLM, HNTRLib2 will not be removed