HP Hitachi Dynamic Link Manager Software Licenses User Manual

Page 312

Advertising
background image

When an LU is deleted via dynamic reconfiguration, path IDs become

inconsecutive, as shown in this example. If you reboot the host, path IDs

might change because they are reconfigured during the reboot.

Adding a Path to an Existing LU by Dynamic Reconfiguration

Note

¢

Only data disks can be reconfigured dynamically. You cannot change

the configuration of boot disks.

This section describes how to dynamically add a path to an existing LU.

1

.

Set a storage system or a switch to make the OS recognize the path.

# cfgadm -c configure ap_id

Check ap_id in the list of configurable hardware information that is

displayed by the cfgadm -al command.
The following is an example of the command:

# cfgadm -al

Ap_Id Type Receptacle

Occupant Cond

system:slot0 cpu/mem connected

configured ok

system:slot1 sbus-upa connected

configured ok

2

.

Check the newly recognized path in the syslog.
The following is an example of the command. Specify the number of lines

to display taking into consideration that three to four lines for each

recognized path are output to the log.

# tail -10 /var/adm/messages

Apr 2 16:02:57 shiga genunix: [ID 408114 kern.info] /pseudo/

dlmndrv@2/dlmfdrv@w50060e8010027a80,5 (dlmfdrv54) online

Apr 2 16:02:57 shiga devfsadmd[89]: [ID 937045 daemon.error]

failed to lookup dev name for /pseudo/dlmndrv@2/

dlmfdrv@w50060e8010027a80,5

Apr 2 16:03:31 shiga scsi: [ID 583861 kern.info] ssd4126 at

fp2: unit-address w50060e8010027a84,5: 642400

Apr 2 16:03:31 shiga genunix: [ID 936769 kern.info] ssd4126 is /

pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0/fp@0,0/

ssd@w50060e8010027a84,5

Apr 2 16:03:31 shiga genunix: [ID 408114 kern.info] /pci@400/

pci@2/pci@0/pci@8/SUNW,qlc@0/fp@0,0/ssd@w50060e8010027a84,5

(ssd4126) online

Apr 2 16:03:31 shiga devfsadmd[89]: [ID 937045 daemon.error]

failed to lookup dev name for /pci@400/pci@2/pci@0/pci@8/

SUNW,qlc@0/fp@0,0/ssd@w50060e8010027a84,5

Apr 2 16:03:36 shiga scsi: [ID 583861 kern.info] ssd4127 at

fp3: unit-address w50060e8010027a84,5: 642400

Apr 2 16:03:36 shiga genunix: [ID 936769 kern.info] ssd4127 is /

pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0,1/fp@0,0/

ssd@w50060e8010027a84,5

Apr 2 16:03:36 shiga genunix: [ID 408114 kern.info] /pci@400/

4-44

HDLM Operation

Hitachi Dynamic Link Manager (for Solaris) User Guide

Advertising
This manual is related to the following products: