If you omit the intermittent error monitoring interval or the number of

times that the error is to occur, each setting is specified as follows:

¢

When the intermittent error monitoring interval or the number of

times that the error is to occur has not been specified before:
The intermittent error monitoring interval is set to 30 minutes, and

the number of times that the error is to occur is set to 3.

¢

When the intermittent error monitoring interval or the number of

times that the error is to occur has been specified before:
The values specified from the last time are used.

When a value of 2 or more is specified for the number of times, the

following condition must be satisfied:

error-monitoring-interval >= checking-interval-for-automatic-

failback x number-of-times-error-is-to-occur-during-intermittent-

error-monitoring

If this condition is not satisfied, the KAPL01080-W message will be output

and an error will occur. If this happens, change any of the following

settings: the checking interval for automatic failback, intermittent error

monitoring interval, or the number of times that the error is to occur.
When you set the number of times that the error is to occur to 1, the

above condition does not need to be satisfied.
The following shows the sub-parameters that should be specified: the

error monitoring interval and the number of times that the error is to

occur:

-intvl error-monitoring-interval

Specify the monitoring interval for an intermittent error. Use a value

from 1 to 1440 minutes. The default is 30.
During intermittent error monitoring, if changes are made in the

settings of the intermittent error monitoring interval, the error count

and the elapsed time measured since monitoring starts are set to 0,

and monitoring starts by using the new settings.
Outside the duration of intermittent error monitoring, if changes are

made in the settings of the intermittent error monitoring interval, the

new settings take effect after the next time automatic failback

succeeds. Outside the duration of intermittent error monitoring, the

number of errors that determine an intermittent error is not counted

and this value is not changed.
The monitoring interval specified in this parameter is stored even

though specifying -iem off disables intermittent error monitoring.

Therefore, when you re-enable intermittent error monitoring and a

monitoring interval is not specified, error monitoring will be performed

by using the stored monitoring interval.

-iemnum number-of-times-error-is-to-occur

Specify the number of times the error is to occur. Valid values are

from 1 to 99. The default is 3.