the change, use the following table to obtain the value to be specified,

and then change the current value to a value equal to or greater than

the value you have obtained.

Table 3-16 Formula for Calculating DISKTIMEOUT

Storage system type

Number

of paths

connecte

d to the

voting

disk

Formula for obtaining the value of

DISKTIMEOUT

Lightning 9900V series

Hitachi USP series

Universal Storage

Platform V/VM series

Virtual Storage Platform

series

VSP G1000 series

HUS VM

3 or less

You do not need to change the value

of DISKTIMEOUT.

4 or more number-of-paths-connected-to-the-

voting-disk x 60 seconds

Hitachi

AMS2000/AMS/WMS/SM

S series

HUS100 series

Thunder 9500V series

6 or less

You do not need to change the value

of DISKTIMEOUT.

7 or more number-of-paths-connected-to-the-

voting-disk x 30 seconds

For details on how to change MISSCOUNT and DISKTIMEOUT, contact

the company with which you have a contract for Oracle Support

Services.
Note that when you remove HDLM from the above configuration, you

must reset the values of MISSCOUNT and DISKTIMEOUT to their original

values. Therefore, make a note of the original values of MISSCOUNT

and DISKTIMEOUT before changing them.

In Oracle RAC 11g, for the following devices, device name should be

matching between the nodes:

¢

voting disk

¢

Oracle Cluster Registry

¢

Oracle database file

¢

system table area

¢

users table area

¢

ASM disk to be used for ASM disk group creation

In an environment where an HDLM raw device is used as the devices

listed above, if the HDLM raw device name does not match between the

nodes, create an alias device file of the HDLM raw device in each node by

using the following procedure and set the created alias device file in

Oracle RAC 11g.