Parameters, To display the format of the offline operation -7, Parameters -7 – HP Hitachi Dynamic Link Manager Software Licenses User Manual

Page 355: To place paths offline -7

Advertising
background image

|-pathid AutoPATH_ID
|-device SCSI-device-name}
[-s]

To display the format of the offline operation

/opt/DynamicLinkManager/bin/dlnkmgr offline -help

Parameters

To place paths offline

-path

Indicates that the target of the operation is a path managed by HDLM.
This parameter is optional because offline is always used for paths, so it

is assumed.
Make sure that you specify the paths to be taken offline by using the -
hba, -hbaid, -cha, -chaid, -pathid, or -device parameter.

-hba host-port-number.bus-number

Use this parameter to place offline, at one time, all the paths that pass

through a specific HBA port. The command will place offline all the paths

connected to the HBA port that has the specified host port number and

bus number.
Specify the host port number and bus number of the target HBA port: the

numbers are found in the PathName field displayed using the view

operation. Enter a period between these two parameter values. For

details on the view operation, see

view (Displays Information) on page

6-34

.

Example

The following example shows how to place offline all paths connected

to the HBA port whose host port number is 0001 and bus number is
0000:

# /opt/DynamicLinkManager/bin/dlnkmgr offline -hba 0001.0000

KAPL01055-I All the paths which pass the specified HBA will

be changed to the Offline(C) status. Is this OK? [y/n]:y

KAPL01056-I If you are sure that there would be no problem

when all the paths which pass the specified HBA are placed in

the Offline(C) status, enter y. Otherwise, enter n. [y/n]:y

KAPL01061-I 3 path(s) were successfully placed Offline(C); 0

path(s) were not. Operation name = offline

#

-hbaid HBA-port-ID

Use this parameter to place offline, at one time, all paths that pass

through a specific HBA port. The command will place offline all paths

connected to the HBA port that has the specified HBA-port-ID. To display

the HBA port IDs, execute the following view operation:

Command Reference

6-7

Hitachi Dynamic Link Manager (for Solaris) User Guide

Advertising