Diagnostic corrective actions -93 – JLG 510AJ Service Manual User Manual

Page 135

Advertising
background image

SECTION 3 - CHASSIS AND TURNTABLE

3121181

– JLG Lift –

3-93

Diagnostic Calibration Configuration and
Corrective Actions

Each fault within the DGC is capable of being uniquely config-
ured in the engine.s diagnostic calibration to cause one or

more corrective actions while a given fault is active. Table 2
identifies the configuration options and corrective actions
available for configuration of each fault. The desired action is
set by the OEM calibration engineers.

Table 3-11. Diagnostic Corrective Actions

CORRECTIVE

ACTION

DESCRIPTION

Enable

Enables the fault for fault detection

Shutdown

Cause an engine shutdown when fault becomes active

Never Forget

Retain fault as historic/previously active until cleared by a technician and does not allow historic fault to be “auto-cleared”

Turn on MIL

Turn on MIL output when fault becomes active

CL Disable

Disable closed-loop while the fault is active

CL Disable Key- Cyc

Disable closed-loop while the fault is active and for the remainder of the key cycle

AL Disable

Disable adaptive learn while the fault is active

AL Disable Key-Cyc

Disable adaptive learn while the fault is active and for the remainder of the key cycle

Power Derate 1

Limit TPS to the Power Derate 1 percent set in the diagnostic calibration while the fault is active. The Power Derate 1 TPS percent should be set higher
than Power Derate 2 as Power Derate 2 adds a higher level of protection.

Power Derate 2

Limit TPS to the Power Derate 2 percent set in the diagnostic calibration while the fault is active. If the calibration is set to “Latched for Key-Cycle”
Power Derate 2 remains active until engine speed and FPP conditions are satisfied. The Power Derate 2 TPS percent should be set lower than Power
Derate 1 as Power Derate 2 adds a higher level of protection.

Low Rev Limit

Limit RPM to the Low Rev Limit speed set in the diagnostic calibration while the fault is active. If the calibration is set to “Latched for Key-Cycle” Low
Rev Limit remains active until engine speed and FPP conditions are satisfied.

Forced Idle

Limit RPM to the Forced Idle speed set in the diagnostic calibration while the fault is active and for the remainder of the key cycle

Soft Warning

Turn on the soft warning output when the fault becomes active

Hard Warning

Turn on the hard warning output when the fault becomes active

Stopped Check

Run fault detection/checking while the engine is in a key-on, engine-off condition. NOTE: It is recommended that this feature only be used for general
sensor faults (high/low voltage) and some output drivers

Advertising