SECTION 6 - JLG CONTROL SYSTEM

3121181

– JLG Lift –

6-25

19

LOAD TYPE

Selects if we are
using the LSS
Module, built in
load cell or the
BPE module (if
selected model
uses the Gorilla
Platform Mod-
ule)
NOTE: Not dis-
played if LOAD: is
0=NO

0=1 ON ROTATOR

Use the on-board load sensor for all models
except those models which use the Gorilla Plat-
form Module, which use the BPE module inter-
face for Platform load sensing

0

1=4 UNDER BASKET

Use the LSS Module

20

ANGLE:

Displays pres-
ence/function of
angle sensor
NOTE: 2=ANA-
LOG Not Dis-
played

1=DIGITAL

1 Limit switches are installed or switches are
not present on this model

1

2=ANALOG

2 An analog sensor is installed

21

LENGTH:

Displays pres-
ence/function of
length sensor
NOTE: 2=ANA-
LOG Not Dis-
played

1=DIGITAL

Limit switch installed or switches are not present
on this model

1

2=ANALOG

2 An analog sensor is installed

22

FUNCTION
CUTOUT:

Displays pres-
ence/function of
drive cutout.

0=NO

No Drive Cutout

0

1=BOOM CUTOUT

Boom Function Cutout While Driving Above Ele-
vation. (CE)

2=DRIVE CUTOUT

Drive Cutout Above Elevation

3=DRIVE CUT E & T

Drive Cutout Above Elevation And Tilted

23

GROUND
ALARM:

Displays/adjusts
ground alarm
presence/func-
tion

0=NO

No Ground Alarm installed

0

1=DRIVE

Travel alarm – sounds when the drive function is
active. (Option)

2=LIFT DOWN

Descent alarm – sounds when either lift down is
active. (Option)

3=BOOM & DRIVE

Motion alarm – sounds when any function is
active. (Option)

24

T PROX
SWITCHES:

Displays pres-
ence/function of
Tower Proximity
switches.

0=NO

No Tower Prox Switches Installed

0

1=YES

Tower Prox Switches Installed

Table 6-1. Machine Set-Up Parameters

Configurati

on

Digit

Parameter

Displayed on

Analyzer

Line 1

Description

Parameter

Value

Definition

Defaul

t

Numb

er