SECTION 6 - JLG CONTROL SYSTEM

3121181

– JLG Lift –

6-45

STARTER LOCKOUT:
6

0

1

DISABLED: Automatic pre-glow time determined by ambient air temperature;
engine start can be attempted at any time during pre-glow.

ENABLED: Automatic pre-glow time determined by ambient air temperature;
engine start is NOT permitted until pre-glow is finished.

0

Fuel Cutout
7

0

1

2

RESTART: Engine allowed to be restarted multiple times when very low
fuel level is reached.

ONE RESTART: Engine allowed to be restarted once for 2 minutes when very
low fuel level is reached.

ENGINE STOP: Engine not able to restart when very low fuel level is reached.

0

*This menu item is only visible if non-dual fuel engines are selected.

ENGINE SHUTDOWN:
8*

0

1

DISABLED: No engine shutdown.

ENABLED: Shutdown engine when coolant temperature is greater than 110 deg.
C or the oil pressure is less than 8 PSI.

1

TILT:
9*

1

2

3

4

5

6

5 DEGREES: Reduces maximum speed of all boom functions to creep when tilted
more than 5 degrees and above elevation; also reduces drive speed to creep.

4 DEGREES: Reduces maximum speed of all boom functions to creep when tilted
more than 4 degrees and above elevation; also reduces drive speed to creep.

3 DEGREES: Reduces maximum speed of all boom functions to creep when tilted
more than 3 degrees and above elevation; also reduces drive speed to creep.

4 DEGREES + CUT: Reduces maximum speed of all boom functions to creep
when tilted more than 4 degrees and above elevation; also disallows tower lift
up, tower telescope out, drive, main telescope out and main lift up.

3 DEGREES + CUT: Reduces maximum speed of all boom functions to creep
when tilted more than 3 degrees and above elevation; also disallows tower lift
up, tower telescope out, drive, main telescope out and main lift up.

5 DEGREES + CUT: Reduces the maximum speed of all boom functions to

creep when tilted more than 5 degrees and above elevation; also disallows
tower lift up, tower telescope out, drive, main telescope out and main lift up.

1

* Certain market selections will limit tilt options and alter default setting.

Note: Any of the selections above will light the tilt lamp when a tilted condition occurs and will sound the platform alarm when the machine is
also above elevation.