JLG 510AJ Service Manual User Manual

Page 339

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121181

– JLG Lift –

6-57

TEST ALL INPUTS?

Prompts whether to check every operator input. If ESC is pressed or
clicked, the system test ends. If ENTER is pressed or clicked, each opera-
tor input is prompted for in turn.
In platform mode every platform switch and joystick is tested.
In ground mode every ground switch is tested.
NOTE: Tower lift switches are not tested if TOWER LIFT=NO. Tower tele-
scope switches are not tested if TOWER TELE=NO. Jib switches are not
tested if JIB = NO. Extendable axle switches are not tested if EXT
AXLES=NO. Four wheel steer switches are not tested if 4WS=NO.
NOTE: Left/right jib switches are not tested unless JIB = SIDESWING.
Prompts displayed during the operator input test below messages.

CLOSE XXXXXXX

The named switch should be closed.

OPEN XXXXXXX

The named switch should be opened.

XXXXXXX XXXXXXX TO MAX

The named joystick should be pushed to its full extent in the named
direction.

XXXXXXX XXXXXXX TO MIN

The named joystick should be returned to neutral from the named direc-
tion.

PUMP POT TO MAX

The pump pot should be turned to maximum.

PUMP POT TO MIN

The pump pot should be turned to minimum.

MULTIPLE CLOSURE

More than one operator input is closed; if only one has been operated,
there could be a short between two inputs.

TESTS COMPLETE

Indicates that the system test is complete. Any problems reported
should have been noted and should now be rectified. Press ESC/CANCEL
to return to the RUN SYSTEM TEST Analyzer menu.

Table 6-7. System Test Messages

Message Displayed on

Analyzer

Message Displayed on

Analyzer

Description