JLG 510AJ Service Manual User Manual

Page 306

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-24

– JLG Lift –

3121181

10

EXT. AXLES:

Displays/adjusts
extendable axle
presence. NOTE:
Not Displayed

0=NO

No Extendable Axles installed

0

1=YES

1 Yes

11

4WS:

Displays/adjusts
4 wheel steer
presence

0=NO

No 4 wheel steer installed

0

1=YES

Yes

12

JIB BLOCK:

Displays pres-
ence of jib block
limit switch.
NOTE: Not Dis-
played

0=NO

No Jib Block switch

0

1=YES

1 Yes

13

SOFT
TOUCH:

Displays pres-
ence of soft
touch system

0=NO

No Soft Touch System installed

0

1=YES

Yes

14

GEN SET/
WELDER:

Displays/adjusts
presence of gen-
erator/welder

0=NO

No Generator/welder installed

0

1=BELT DRIVE

Belt drive generator/welder installed

2=HYD DRIVE

Hydraulic driven generator/welder installed

15

H & T LIGHTS:

Displays pres-
ence of head and
tail lights

0=NO

No Head and Tail Lights installed

0

1=YES

Yes

16

CABLE
SWITCH:

Displays pres-
ence of broken
cable switch

0=NO

No Broken Cable Switch installed

0

1=YES

Yes

17

TURNTABLE
POSITION
SWITCH:

Displays pres-
ence of turntable
position switch.
NOTE: Not Dis-
played

0=NO

No Turntable Position Switch installed

0

1=YES

1 Yes

18

LOAD:

Displays pres-
ence/function of
load sensor

0=NO

No load sensor installed.

0

1=WARN ONLY

Boom and drive function in creep, overload lamp
lit, Platform Alarm sounds continuously

2=WARN & CUTOUT

All functions cutout, flash overload light (500mS
on, 500mS off ), Platform Alarm beeps (5 sec on,
55 sec off, 5 sec on)

3=SPECIAL 1

As 1=WARN ONLY, but disable upper telescope
out and upper lift up

Table 6-1. Machine Set-Up Parameters

Configurati

on

Digit

Parameter

Displayed on

Analyzer

Line 1

Description

Parameter

Value

Definition

Defaul

t

Numb

er

Advertising