SECTION 6 - JLG CONTROL SYSTEM

6-48

– JLG Lift –

3121181

DRIVE:
21*

0

1

2

4WD: Four wheel drive.

2WD: Two wheel drive.

2WD W/ 2-SPEED: Two wheel drive with 2-speed valve.

0

* Only visible under certain model selections.

DISPLAY UNITS:
22*

0

1

IMPERIAL: DEG F, PSI, LBS

METRIC: DEG C, KPA, KGS

0

* Certain market selections will alter default setting.

LEVELING MODE:
23*

0

1

ALL FUNCTIONS: Platform level with all functions.

LEVEL LIFT/TELESCOPE: Platform level on lift and telescope only.

0

* Only visible on 800S models.

DRIVE CONTROL:
24

0

1

2

NORMAL: Drive coils are energized from the Ground Module.

PROPULSION: Drive coils are energized from the Propulsion Module.

ENHANCED: Drive coils are energized from the Ground Module and the ground
side of the drive coils are brought back to current feedback
returns.

2

DRIVE PUMP:
25*

0

1

SAUER DANFOSS: Machine equipped with Sauer Danfoss drive pump.

EATON: Machine equipped with Eaton drive pump.

0

* Only visible on 800S models.

BOOM CONTROL:
26

0

1

NORMAL: Boom function coils are energized from the Ground Module.

ENHANCED: Boom function are energized from the Ground Module and the
ground side of the drive coils are brought back to current feedback returns.

0

FUNCTION SPEED
KNOB:
27

0

1

YES: Machine is equipped with Function Speed Knob.

NO: Machine is equipped with Operation Speed Switch.

0

Table 6-6. Machine Configuration Programming Information Software Version P6.1 to Present

Configuration Label/

Digit

Number

Description

Default

Number

Advertising