SECTION 1 - SPECIFICATIONS

1-6

– JLG Lift –

3121181

*If necessary install grease fittings into worm gear
housing and grease bearings.

DO NOT OVER-GREASE END BEARINGS. OVER-GREASING
BEARINGS WILL BLOW OUTER SEAL IN HOUSING.

3.

Wheel Bearings (2WD Only)

Lube Point(s) - Repack
Capacity - A/R
Lube - MPG
Interval - Every 2 years or 1200 hours of operation

4.

Wheel Drive Hub

Lube Point(s) - Level/Fill Plug
Capacity - 17 oz. (0.5 L) - 1/2 Full
Lube - EPGL
Interval - Check level every 3 months or 150 hrs of
operation; change every 2 years or 1200 hours of
operation.

5.

Hydraulic Return Filter

Interval - Change after first 50 hrs. and every 6
months or 300 hrs. thereafter or as indicated by
Condition Indicator.

6.

Hydraulic Charge Filter

Interval - Change after first 50 hrs. and every 6
months or 300 hrs. thereafter or as indicated by
Condition Indicator.

7.

Hydraulic Tank

Advertising