9 machine personality settings, Machine personality settings -27, Personality ranges/defaults -27 – JLG 510AJ Service Manual User Manual
Page 309
SECTION 6 - JLG CONTROL SYSTEM
3121181
– JLG Lift –
6-27
6.9
MACHINE PERSONALITY SETTINGS
NOTE:
Personality settings can be adjusted within the adjustment
range in order to achieve optimum machine performance.
Table 6-2. Personality Ranges/Defaults
FUNCTION
PERSONALITY
RANGE
DEFAULTS
DRIVE
ACCELeration
0.1s to 5.0s
1.5
DECELeration
0.1s to 3.0s
1.5
MINimum speed
0 to 35%
30
MAXimum speed
0 to 100%
50
REVerse MINimum speed
0 to 35%
30
REVerse MAXimum speed
0 to 100%
50
ELEVATED MAXimum speed
0 to 50%
38
CREEP MAXimum speed
0 to 50%
40
Engine RPM
800 to 2900
1800
TOWER LIFT
ACCELeration
0.1 to 5.0
1.0
DECELeration
0.1 to 3.0
1.0
MlNimum UP speed
0 to 60%
28
MAXimum UP speed
0 to 100%
45
MINimum DOWN speed
0 to 60%
27
MAXimum DOWN speed
0 to 100%
42
Engine RPM
800 to 2900
1800
UPPER LIFT
ACCELeration
0.1 to 5.0
2.0
DECELeration
0.1 to 3.0
1.0
MlNimum UP speed
0 to 60%
36
MAXimum UP speed
0 to 100%
50
CREEP Maximum UP speed
0 to 65%
40
MINimum DOWN speed
0 to 60%
29
MAXimum DOWN speed
0 to 100%
48
CREEP maximum DOWN speed
0 to 75%
37
Engine RPM
800 to 2900
1800