6.9

MACHINE PERSONALITY SETTINGS

NOTE:

Personality settings can be adjusted within the adjustment
range in order to achieve optimum machine performance.

Table 6-2. Personality Ranges/Defaults

FUNCTION

PERSONALITY

RANGE

DEFAULTS

DRIVE

ACCELeration

0.1s to 5.0s

1.5

DECELeration

0.1s to 3.0s

1.5

MINimum speed

0 to 35%

30

MAXimum speed

0 to 100%

50

REVerse MINimum speed

0 to 35%

30

REVerse MAXimum speed

0 to 100%

50

ELEVATED MAXimum speed

0 to 50%

38

CREEP MAXimum speed

0 to 50%

40

Engine RPM

800 to 2900

1800

TOWER LIFT

ACCELeration

0.1 to 5.0

1.0

DECELeration

0.1 to 3.0

1.0

MlNimum UP speed

0 to 60%

28

MAXimum UP speed

0 to 100%

45

MINimum DOWN speed

0 to 60%

27

MAXimum DOWN speed

0 to 100%

42

Engine RPM

800 to 2900

1800

UPPER LIFT

ACCELeration

0.1 to 5.0

2.0

DECELeration

0.1 to 3.0

1.0

MlNimum UP speed

0 to 60%

36

MAXimum UP speed

0 to 100%

50

CREEP Maximum UP speed

0 to 65%

40

MINimum DOWN speed

0 to 60%

29

MAXimum DOWN speed

0 to 100%

48

CREEP maximum DOWN speed

0 to 75%

37

Engine RPM

800 to 2900

1800