SECTION 6 - JLG CONTROL SYSTEM

3121181

– JLG Lift –

6-47

LOAD SYSTEM:
17*

0

1

2

3

4

NO: No load sensor installed.

WARN ONLY: Functions in creep, overload lamp lit, platform alarm beeps (5 sec
ON, 2 sec OFF).

CUTOUT PLATFORM: All functions cutout, overload lamp lit, platform alarm
beeps (5 sec ON, 2 sec OFF).

CUTOUT ALL: All functions cutout, flash overload light (500mS on, 500mS off ),
platform alarm beeps (5 sec ON, 2 sec OFF).

SPECIAL 1: Functions in creep, overload lamp lit, disables main telescope out &
main lift up, platform alarm beeps (5 sec ON, 2 sec OFF).

0

* Only visible under certain market selections.
* Certain market selections will limit load system options or alter default setting.

LOAD SENSOR:
18*

0

1

1 ON ROTATOR: Use the on-board load sensor for all models except those which
use the Leveling Platform Module.

4 UNDER PLATFORM: Use the EIM for load sensing.

1

* Only visible if Load Sensor Menu selection is not 0 and under certain market selections.
* Certain market selections will limit load sensor options.

FUNCTION CUTOUT:
19*

0

1

2

3

NO: No drive cutout.

BOOM CUTOUT: Boom function cutout while driving above elevation.

DRIVE CUTOUT: Drive & steer cutout above elevation.

DRIVE CUT E&T: Drive & steer cutout above elevation and tilted.

0

* Only visible under certain market selections.
* Certain market selections will limit function cutout options or alter default setting.

GROUND ALARM:
20*

0

1

2

3

NO: No ground alarm installed.

DRIVE: Travel alarm sounds when the drive function is active (Option).

DESCENT: Descent alarm sounds when lift down is active (Option).

MOTION: Motion alarm sounds when any function is active (Option).

3

* Certain market selections will alter default setting.

Table 6-6. Machine Configuration Programming Information Software Version P6.1 to Present

Configuration Label/

Digit

Number

Description

Default

Number