Table 6-8. Machine Diagnostics Parameters

Diagnostics

Submenu

(Displayed on

Analyzer 1

st

Line)

Parameter

(Displayed on

Analyzer 2

nd

Line)

Parameter Value

(Displayed on Analyzer 2

nd

Line)

Description

DRIVE:

DRIVE

FOR/REV XXX%

Displays drive joystick direction & demand

STEER

RIGHT/LEFT XXX%

Displays steer switch direction & demand

4WS

NORMAL/COOR/CRAB

Displays status of four wheel steer input (Displayed if 4WS
= 1)

BRAKES

LOCKED/RELEASED

Displays brake control system status

CREEP

ACTIVE/NOT ACTIVE

Displays pump pot creep switch status

CRP MODE

ACTIVE/NOT ACT

Displays creep mode status

QPRX1

ACTIVE/NOT ACTIVE

Displays status of Q-Prox sensor in drive joystick (Dis-
played if JOYSTICK TYPE = 1)

QPRX2

ACTIVE/NOT ACTIVE

Displays status of Q-Prox sensor in drive joystick (Dis-
played if JOYSTICK TYPE = 1)

TWO SPEED

OP/CL

Displays status of two speed switch input if selected
model has two speed.

2 speed mode

ON/OFF

Displays status of two speed valve if selected model has
two speed

high engine

OP/CL

Displays status of high engine switch

LT F ANG

XX.X

Displays status of left front steer angle (Displayed if
MODEL NUMBER = 7 or 8)

RT F ANG

XX.X

Displays status of right front steer angle (Displayed if
MODEL NUMBER = 7 or 8)

LT R ANG

XX.X

Displays status of left rear steer angle (Displayed if MODEL
NUMBER = 7 or 8)

RT R ANG

XX.X

Displays status of right rear steer angle (Displayed if
MODEL NUMBER = 7 or 8)

DOS LIM sw

OP/CL

Displays status of Drive Orientation System limit switch.
(Displayed if MODEL NUMBER = 7 or 8)

DOS O/R sw

OP/CL

Displays status of Drive Orientation Limit System override
switch. (Displayed if MODEL NUMBER = 7 or 8)