JLG 510AJ Service Manual User Manual

Page 358

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-76

– JLG Lift –

3121181

3/4

Flash code 3/4 indicates a driver problem on a platform valve
block valve driver. All driver faults are detected in a similar man-
ner. Open circuit faults are detected when the analog feedback
reads too high and output is commanded off. Short to ground is
detected when analog feedback reads low and output is com-
manded on. Short to battery is detected when analog feedback
reads Vbat and output is commanded off. Not reported during 2
second power-up. An EMS cycle is required.

6

BASKET UP SHORT TO BATTERY

BASKET UP SHORT TO GROUND

BASKET UP OPEN CIRCUIT

BASKET UP SHORT TO BATTERY OR
OPEN CIRCUIT

Only occurs on machines with electronic basket leveling

BASKET DOWN SHORT TO BATTERY

BASKET DOWN SHORT TO GROUND

bASKET DOWN OPEN CIRCUIT

BASKET DOWN SHORT TO BATTERY OR
OPEN CIRCUIT

Only occurs on machines with electronic basket leveling.

BASKET LEFT SHORT TO BATTERY

BASKER LEFT SHORT TO GROUND

BASKET LEFT OPEN CIRCUIT

BASKET RIGHT SHORT TO BATTERY

BASKET RIGHT SHORT TO GROUND

BASKET RIGHT OPEN CIRCUIT

JIB UP SHORT TO BATTERY

JIB UP SHORT TO GROUND

JIB UP OPEN CIRCUIT

JIB DOWN SHORT TO BATTERY

JIB DOWN SHORT TO GROUND

JIB DOWN OPEN CIRCUIT

JIB LEFT SHORT TO BATTERY

JIB LEFT SHORT TO GROUND

JIB LEFT OPEN CIRCUIT

JIB RIGHT SHORT TO BATTERY

JIB RIGHT SHORT TO GROUND

JIB RIGHT OPEN CIRCUIT

PLATFORM CONTROL VALVE SHORT TO
BATTERY

Only occurs on machines with electronic basket leveling

PLATFORM CONTROL VALVE SHORT TO
GROUND

Only occurs on machines with electronic basket leveling

PLATFORM CONTROL VALVE OPEN CIR-
CUIT

Only occurs on machines with electronic basket leveling

3/5

Flash code 3/5 indicates a brake pressure problem.
NOT REQUIRED

Table 6-9. Help Fault Codes, Displayed Faults, and Descriptions

Fault Flash

Code

Analyzer Display

Description

Priority

Advertising