Table 6-1. Machine Set-Up Parameters

Configurati

on

Digit

Parameter

Displayed on

Analyzer

Line 1

Description

Parameter

Value

Definition

Defaul

t

Numb

er

1

MODEL
NUMBER:

Displays/adjusts
machine model

1=400

400

1

2=450, 510

2=450, 510

3=600

3=600

4=601

4=601

5=800A

5=800A

6=800S

6=800S

7=1350S

7=1350S

8=1200S

8=1200S

1A

ENVELOPE
HEIGHT:

Displays/adjusts
envelope height.
Only displayed if
MODEL NUMBER
= 7 or 8.

1=1350S/135’MAX

1350S 135’ Envelope (Model 1350 only)

1 or 5,
per
MODE
L
NUM-
BER
selec-
tion

2=1350S/125’MAX

1350S 125’ Envelope (Model 1350 only)

3=1350S/120’MAX

1350S 120’ Envelope (Model 1350 only)

4=1350S/110’MAX

1350S 110’ Envelope (Model 1350 only

5=1200S/120’MAX

1200S 120’ Envelope (Model 1200 only)

6=1200S/110’MAX

1200S 110’ Envelope (Model 1200 only)

2

ENGINE:

Displays/adjusts
engine manufac-
turer/type

1=FORD EFI GAS

Ford LRG425EFI Gas

2

2=FORD EFI D/F

Ford LRG425EFI Gas with dual fuel

3=DEUTZ F4

Deutz F4M1011F, F4M2011, or BF4M2011 Diesel

4=DEUTZ F3

Deutz F3M1011F or F3M2011 Diesel

3

GLOW PLUG:

Display/adjusts
glow plug pres-
ence and on-
time. Only dis-
played if ENGINE
= 3 or 4

0=NO GLOW PLUGS

0 No glow plugs installed

0

2=”XX=XX SEC-
ONDS”

1-60Setting this number tells the controller how
many seconds after the EMS is pulled to output
to the glow plugs before permitting the engine
to be started

4

ENG SHUT-
DOWN:

Displays/adjusts
presence of the
engine shut-
down feature.

0=NO

No engine shutdown

1

1=SHUTDOWN

Shutdown engine when coolant temperature is
greater than 118° C (for the FORD engine) or the
oil pressure is less than 8 psi.

Advertising