SECTION 6 - JLG CONTROL SYSTEM

3121181

– JLG Lift –

6-71

3/3

Flash code 3/3 indicates a driver problem. All driver faults are
detected in a similar manner. Open circuit faults are detected
when the analog feedback reads too high and the output is com-
manded off. Short to ground is detected when the analog feed-
back reads low and the output is commanded on. Short to
battery is detected when the analog feedback reads Vbat and
the output is commanded off. Not reported during 2 second
power-up. An EMS cycle is required.

6

RIGHT FORWARD DRIVE PUMP SHORT
TO GROUND

Only occurs on machines with a chassis module.

RIGHT FORWARD DRIVE PUMP SHORT
TO BATTERY

Only occurs on machines with a chassis module.

RIGHT FORWARD DRIVE PUMP OPEN
CIRCUIT

Only occurs on machines with a chassis module.

RIGHT REVERSE DRIVE PUMP SHORT TO
GROUND

Only occurs on machines with a chassis module.

RIGHT REVERSE DRIVE PUMP SHORT TO
BATTERY

Only occurs on machines with a chassis module.

RIGHT REVERSE DRIVE PUMP OPEN CIR-
CUIT

Only occurs on machines with a chassis module.

LEFT FORWARD DRIVE PUMP SHORT TO
GROUND

Only occurs on machines with a chassis module.

LEFT FORWARD DRIVE PUMP SHORT TO
BATTERY

Only occurs on machines with a chassis module.

LEFT FORWARD DRIVE PUMP OPEN CIR-
CUIT

Only occurs on machines with a chassis module.

LEFT REVERSE DRIVE PUMP SHORT TO
GROUND

Only occurs on machines with a chassis module.

LEFT REVERSE DRIVE PUMP SHORT TO
BATTERY

Only occurs on machines with a chassis module.

LEFT REVERSE DRIVE PUMP OPEN CIR-
CUIT

Only occurs on machines with a chassis module.

ALTERNATOR/ECM POWER SHORT TO
GROUND

HOUR METER SHORT TO GROUND

HOUR METER SHORT TO BATTERY

HORN SHORT TO GROUND

HORN OPEN CIRCUIT

HORN SHORT TO BATTERY

AUX POWER SHORT TO GROUND

AUX POWER OPEN CIRCUIT

AUX POWER SHORT TO BATTERY

GLOW PLUG SHORT TO GROUND

Only occurs on machines with glowplugs configured.

GLOW PLUG OPEN CIRCUIT

Only occurs on machines with glowplugs configured.

GLOW PLUG SHORT TO BATTERY

Only occurs on machines with glowplugs configured.

LP LOCK SHORT TO GROUND

Only occurs on machines with dual-fuel engines.

LP LOCK OPEN CIRCUIT

Only occurs on machines with dual-fuel engines.

Table 6-9. Help Fault Codes, Displayed Faults, and Descriptions

Fault Flash

Code

Analyzer Display

Description

Priority