SECTION 6 - JLG CONTROL SYSTEM

6-68

– JLG Lift –

3121181

2/2

Flash code 2/2 indicates problems with drive & steer selection.
Except where noted, these faults are not reported during 2 sec-
ond power-up sequence.

3

DRIVE LOCKED – JOYSTICK MOVED
BEFORE FOOTSWITCH

Drive was selected before and during footswitch closure. Can be
reported during power-up sequence.

FSW INTERLOCK TRIPPED

Footswitch was closed for seven seconds with no function selected.
Can be reported during power-up sequence.

STEER LOCKED – SELECTED BEFORE
FOOTSWITCH

Steer was selected before and during footswitch closure.

STEER SWITCHES FAULTY

Both steer switches are active at the same time.

D/S JOY. OUT OF RANGE LOW

Resistive joysticks: These faults do not occur.

D/S JOY. OUT OF RANGE LOW

Resistive joysticks: These faults do not occur.

D/S JOY. OUT OF RANGE HIGH

Resistive joysticks: These faults do not occur if the Vref voltage is
below 8.1 volts. If Vref is above 7.7 volts, Vref is operating out of toler-
ance or a short to battery has occurred.

D/S JOY. CENTER TAP BAD

Resistive joysticks: These faults occur when the center tap voltage is
not between 3.08 volts and 3.83 volts. Due to resistor tolerances
there is a +/-.1 volt range around these values where the fault may be
indicated.

WAITING FOR FSW TO BE OPEN

Footswitch was closed when platform mode was selected. Can be
reported during power-up sequence.

FOOTSWITCH SELECTED BEFORE START The user attempted to start the machine with the

footswitch engaged.

Table 6-9. Help Fault Codes, Displayed Faults, and Descriptions

Fault Flash

Code

Analyzer Display

Description

Priority