Exhaust venturi adjustment -154, Ab c d – JLG 510AJ Service Manual User Manual

Page 196

Advertising
background image

SECTION 3 - CHASSIS AND TURNTABLE

3-154

– JLG Lift –

3121181

A

B

C

D

A. Exhaust Venturi

B. 1/4" (6.35 mm) minimum clearance all around.

C. 3/4" (19.05 mm) minimum engagement

D. Exhaust Pipe Outlet

NOTE:

Outlet pipe must be centered within 1/4" (6.35 mm) minimum
clearance to the exhaust venturi all around venturi’s perimeter.
If exhaust pipe touches venturi, it will transfer heat and melt the
hood. If exhaust pipe is not centered, adjust muffler or outlet as
needed to achieve necessary clearance.

Figure 3-78. Exhaust Venturi Adjustment

Advertising