SECTION 6 - JLG CONTROL SYSTEM

3121181

– JLG Lift –

6-41

GEN SET CUTOUT:
13*
* Only visible if Gen Set /
Welder Menu selection
is not 0.

0

1

MOTION ENABLED: Motion enabled when generator is ON.

MOTION CUTOUT: Motion cutout in platform mode only.

0

H & T LIGHTS:
14

0

1

NO: No head and tail lights installed.

YES: Head and tail lights installed.

0

CABLE SWITCH:
15*
* Only visible under cer-
tain model selections.
* Certain market and
model selections will
alter the default setting.

0

1

NO: No broken cable switch installed.

YES: Broken cable switch installed.

0

LOAD SYSTEM:
16*
* Only visible under cer-
tain market selections.
* Certain market selec-
tions will limit load sys-
tem options or alter
default setting.

0

1

2

3

4

NO: No load sensor installed.

WARN ONLY: Functions in creep, overload lamp lit, platform alarm beeps (5
sec ON, 2 sec OFF).

CUTOUT PLATFORM: All functions cutout, overload lamp lit, platform alarm
beeps (5 sec ON, 2 sec OFF).

CUTOUT ALL: All functions cutout, flash overload light (500mS on, 500mS
off ), platform alarm beeps (5 sec ON, 2 sec OFF).

SPECIAL 1: Functions in creep, overload lamp lit, disables main telescope out
& main lift up, platform alarm beeps (5 sec ON, 2 sec OFF).

0

LOAD SENSOR:
17*
* Only visible if Load
Sensor Menu selection
is not 0 and under cer-
tain market selections.
* Certain market selec-
tions will limit load sen-
sor options.

0

1

1 ON ROTATOR: Use the on-board load sensor for all models except those
which use the Leveling Platform Module.

4 UNDER PLATFORM: Use the EIM for load sensing.

1

Table 6-5. Machine Configuration Programming Information Software Version P5.3 to P6.1