JLG 510AJ Service Manual User Manual
Page 367
SECTION 6 - JLG CONTROL SYSTEM
3121181
– JLG Lift –
6-85
8/5
Flash code 8/5 indicates problems with the moment or load pin
system. Only occur on machines with moment or load pin con-
trol. An EMS cycle is required.
10
MOMENT PIN HORIZONTAL FORCE OUT
OF RANGE
The horizontal force is out of the allowed range.
MOMENT PIN VERTICAL FORCE OUT OF
RANGE
The vertical force is out of the allowed range.
LOAD PIN HORIZONTAL FORCE OUT OF
RANGE
The horizontal force is out of the allowed range.
LOAD PIN VERTICAL FORCE OUT OF
RANGE
The vertical force is out of the allowed range.
MOMENT PIN SENSOR FAULT
The moment pin has reported a fault flag.
LOAD PIN SENSOR FAULT
The load pin has reported a fault flag.
NEW MOMENT PIN DETECTED FAULT
A moment pin was detected on the system different from the one
used to calibrate the machine.
NEW LOAD PIN DETECTED FAULT
A load pin was detected on the system different from the one used to
calibrate the machine.
Table 6-9. Help Fault Codes, Displayed Faults, and Descriptions
Fault Flash
Code
Analyzer Display
Description
Priority