SECTION 6 - JLG CONTROL SYSTEM
3121181
– JLG Lift –
6-29
JIB LIFT
ACCELeration
0.1 to 5.0
3.0
DECELeration
0.1 to 3.0
0.5
MINimum UP speed
0 to 65%
16
MAXimum UP speed
0 to 100%
40
MINimum DOWN speed
0 to 65%
16
MAXimum DOWN speed
0 to 100%
27
Engine RPM
800 to 2900
1800
STEER
MAXimum speed
0 to 100%
100
Engine RPM
800 to 2900
1800
GROUND MODE
Tower LIFT UP speed
0 to 100%
42
Tower LIFT DOWN speed
0 to 100%
37
Upper LIFT UP
0 to 100%
50
Upper LIFT DOWN
0 to 100%
60
SWING speed
0 to 100%
60
Upper TELEscope speed
0 to 100%
43
BASKET ROTATE speed
0 to 100%
50
BASKET LEVEL speed
0 to 100%
50
JIB LIFT speed
0 to 100%
25
4150365-3
Table 6-2. Personality Ranges/Defaults