JLG 510AJ Service Manual User Manual

Page 357

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121181

– JLG Lift –

6-75

LIFT DOWN AUX VALVE OPEN CIRCUIT

Only occurs on machines with gravity lift down.

TOWER LIFT APU SHORT TO GROUND

Only occurs on 1250AJP

TOWER LIFT APU OPEN CIRCUIT

Only occurs on 1250AJP

TOWER LIFT APU SHORT TO BATTERY

Only occurs on 1250AJP

MAIN LIFT ENABLE SHORT TO GROUND

Only occurs on 1250AJP

MAIN LIFT ENABLE OPEN CIRCUIT

Only occurs on 1250AJP

MAIN LIFT ENABLE SHORT TO BATTERY

Only occurs on 1250AJP

TOWER TELE APU VALVE STUCK OPEN

Only occurs on 1250AJP

TOWER TELE ENABLE STUCK OPEN

Only occurs on 1250AJP

TOWER TELE APU SHORT TO GROUND

Only occurs on 1250AJP

TOWER TELE APU OPEN CIRCUIT

Only occurs on 1250AJP

TOWER TELE APU SHORT TO BATTERY

Only occurs on 1250AJP

PVG VALVE SHORT TO GROUND

Only occurs on 1250AJP

PVG VALVE OPEN CIRCUIT

Only occurs on 1250AJP

PVG VALVE SHORT TO BATTERY

Only occurs on 1250AJP

FOX SPARE OUTPUT SHORT TO
GROUND

Only occurs on Fox machines.

FOX SPARE OUTPUT SHORT TO BATTERY Only occurs on Fox machines.

FOX SPARE OUTPUT OPEN CIRCUIT

Only occurs on Fox machines.

HOUR METER OPEN CIRCUIT

This fault cannot be detected during normal operation. It may be
reported during self test.

RESTRICTED TO TRANSPORT – AXLE
LOCKOUT VALVE STB OR OC

Only occurs on machines with electrically released oscillating axles
configured. A short to battery or open circuit has been detected on
the axle lockout valve and the machine is restricted to transport
position.

RESTRICTED TO TRANSPORT – PARKING
BRAKE STB

Only occurs on machines with electrically released oscillating axles
configured. A short to battery has been detected on the parking
brake valve and the machine is restricted to transport position.

Table 6-9. Help Fault Codes, Displayed Faults, and Descriptions

Fault Flash

Code

Analyzer Display

Description

Priority

Advertising