SECTION 6 - JLG CONTROL SYSTEM

3121181

– JLG Lift –

6-69

2/3

Flash code 2/3 indicates problems with boom function selec-
tion.

3

LIFT/SWING LOCKED – JOYSTICK
MOVED BEFORE FOOTSWITCH

Platform upper lift or swing was selected before and during foot-
switch closure.

PUMP SWITCHES FAULTY – CHECK
DIAGNOSTICS/BOOM

A boom function (lower lift, telescope, basket level, basket rotate,
jib) has both directions selected together.

PUMP SWITCHES LOCKED – SELECTED
BEFORE FOOTSWITCH

A platform boom function (lower lift, telescope, basket level, basket
rotate, jib) was selected before key switch or footswitch closure.

PUMP SWITCHES LOCKED – SELECTED
BEFORE AUX POWER

A ground boom function (lower lift, telescope, basket level, basket
rotate, jib) was selected before aux power.

l/s joy. out of range low

Resistive joysticks: These faults do not occur.

l/s joy. out of range high

Resistive joysticks: These faults do not occur if the Vref voltage is
below 8.1 volts. If Vref is above 7.7 volts, Vref is operating out of toler-
ance or a short to battery has occurred.

l/s joy. center tap bad

Resistive joysticks: These faults occur when the center tap voltage is
not between 3.08 volts and 3.83 volts. Due to resistor tolerances
there is a +/-.1 volt range around these values where the fault may be
indicated.

PUMP SWITCHES LOCKED – SELECTED
BEFORE START SWITCH

This fault occurs when a hydraulic function switch is closed before
the start switch is closed.

FOOTSWITCH SELECTED BEFORE START The user attempted to start the machine with the footswitch

engaged.

2/4

Flash code 2/4 indicates that steering digital inputs are faulty.
NOT REQUIRED

Table 6-9. Help Fault Codes, Displayed Faults, and Descriptions

Fault Flash

Code

Analyzer Display

Description

Priority

Advertising