SECTION 6 - JLG CONTROL SYSTEM

3121181

– JLG Lift –

6-65

CALIBRATION DATA

BASKET UP

XXX

Displays the basket up calibration point

Basket DOWN

XXX

Displays the basket down calibration point

L FWD DRIVE

XXX

Displays the left forward drive calibration point

R FWD DRIVE

XXX

Displays the right forward drive calibration point

L REV DRIVE

XXX

Displays the left reverse drive calibration point

R REV DRIVE

XXX

Displays the right reverse drive calibration point

F LT STEER

XXX

Displays the forward left steer calibration point

F RT STEER

XXX

Displays the forward right steer calibration point

R LT STEER

XXX

Displays the reverse left steer calibration point

R RT STEER

XXX

Displays the reverse right steer calibration point

U LIFT UP

XXX

Displays the upper lift up calibration point

U LIFT DOWN

XXX

Displays the upper lift down calibration point

U TELE IN

XXX

Displays the upper telescope in calibration point

U TELE OUT

XXX

Displays the upper telescope out calibration point

BM ANG 1 LO

XXX

Displays the boom angle 1 low calibration point

BM ANG 1 HI

XXX

Displays the boom angle 1 high calibration point

BM ANG 2 LO

XXX

Displays the boom angle 2 low calibration point

BM ANG 2 HI

XXX

Displays the boom angle 2 high calibration point

LEN RETRACT

XXX

Displays the length sensor retracted calibration point

LEN EXTEND

XXXXX

Displays the length sensor extended calibration point

LEN WIT

XXXXX

Displays the witness mark calibration point

LEN SWITCH

XXXX

Displays the length switch calibration point

DATALOG:

ON

XXXXhXXm

Displays total controller on (EMS) time

ENGINE

XXXXhXXm

Display engine run time

DRIVE

XXXXhXXm

Displays total controller drive operation time

LIFT

XXXXhXXm

Displays total controller lift operation time

SWING

XXXXhXXm

Displays total controller swing operation time

TELE

XXXXhXXm

Displays total controller telescope operation time

MAX TEMP

XXC

Displays maximum measured ambient temp.

MIN TEMP

XXC

Displays minimum measured ambient temp.

MAX volts

XX.XV

Displays maximum measured battery voltage

RENTAL

XXXXhXXm

Displays total controller operation time. NOTE: can be
reset

ERASE RENTAL?

Not available at Access Level 2.
ENTER resets rental data log time to zero.

Table 6-8. Machine Diagnostics Parameters

Diagnostics

Submenu

(Displayed on

Analyzer 1

st

Line)

Parameter

(Displayed on

Analyzer 2

nd

Line)

Parameter Value

(Displayed on Analyzer 2

nd

Line)

Description