Replacing the lel and co filters – RKI Instruments Gas Tracer User Manual

Page 193

Advertising
background image

Gas Tracer Operator’s Manual

Replacing the LEL and CO Filters • 185

4. Insert the battery pack into the charging station as shown in Figure

26 below so that the metal contacts on the back of the battery pack
come into contact with the metal contacts in the charging station.
When proper contact has been made, the red LED on the charging
station will turn on.

Figure 26: Putting the Battery Pack into the Charging Station

5. When a full charge has been reached, approximately 4 hours, the

red LED on the charging station will turn off. Remove the battery
pack from the charging station and unplug the charging station’s
power cord from the AC outlet.

Replacing the LEL and CO Filters

1. Verify that the Gas Tracer is off.

2. Use a screwdriver to remove the three screws holding the belt clip

to the back side of the instrument. Two of these screws also secure
the flow chamber.

3. Remove the belt clip and unscrew the remaining screw holding in

the flow chamber.

4. Grab the exhaust tube and pull it gently away from the unit to slide

the flow chamber out of the unit. The CO (charcoal) filter may
come out.

5. To replace the LEL filter, remove the old one from its recess in the

sensor gasket and replace it with the new one making sure that it is
properly seated. You do not have to remove the sensor gasket to
replace the LEL filter. It sits in a recess on top of it.

Battery Pack

SDM-2012

BUMP

GX-2012 OFF

COPY

POWER

CAL.

EDIT

ENTER

1SEC ON
3SEC OFF

CHARGE

Advertising