Gas Tracer Operator’s Manual

Bump Testing • 207

8. When AUTO CAL in the BUMP--SET menu item in Maintenance

Mode is set to OFF:

The instrument will display which channels passed or failed
the bump test with a P (pass) or an F (fail) to the right of the
gas.

To view the bump test gas readings press the AIR▲ or
(SHIFT)▼ button. You can scroll between the bump test results
and the bump test gas readings with the AIR▲ or (SHIFT)▼
button.

To return to the BUMP screen in Calibration Mode, press
POWER ENTER.

See “Troubleshooting” on page 175 to investigate the cause of the
failure and replace the failed sensor or sensors if necessary.

Disconnect the tubing from the probe.

F
P
F

%LEL

%

ppm

MAINTENANCE

CH

4

O

2

BUMP

CO

1
12.0
5

%LEL

%

ppm

MAINTENANCE

CH

4

O

2

BUMP

CO


MAINTENANCE

BUMP

Advertising