Appendix b, Technical specifications, Appendix – Rockwell Automation 20M LPM15 Liquid-Cooled Adjustable Frequency AC Drive FRN 2.xxx User Manual

Page 103

Advertising
background image

Appendix

B

Technical Specifications

Table B.A Service Conditions

Table B.B Environmental Conditions

AC Line Distribution System Capacity
(maximum) for 460 VAC Units:

85,000 amps symmetrical fault current capacity. Short
circuit rating may be limited to 65,000 amps if a circuit
breaker is used instead of fuses.

Control Method:

All-digital vector, sinusoidal pulse-width-modulated (PWM)

Displacement Power Factor:

0.96

Line Frequency:

50/60Hz (

±

2 Hz)

Line Voltage Variation:

-10% to +10%

Line Dip Ride-Through:

V/Hz, SVC: Adjustable from 0 to 60 seconds (see
parameter 185)

Motor Lead Lengths:

76 meters (250 feet) total

Remote Operator Control Wire Length:

Up to 303 meters (1000 feet) from the drive

Analog Speed Reference Resolution:

1/1024 (10 bits) 0.1%

Acceleration Adjustment Range:

0.1 to 999.9 seconds (within the ability of current)

Carrier Frequency:

2 kHz, 4 kHz, or 8 kHz (software-selectable)

Current Limit Adjustment:

V/Hz: 50% to 110% (based on drive nameplate rating)

Service Factor:

1.0

Speed Adjustable Range:

From 0 RPM to maximum speed

Speed Regulation:

V/Hz: Motor slip dependent

Speed Reference Resolution:

1 RPM with local keypad, -4095 to +4095 counts with a
network or serial reference

Torque Control Response:

180 to 220 Hz

Torque Linearity:

+3% with optimal parameter setting (typical)

Condition

Specification

Operating Temperature (inside an enclosure):

0

to 55°C

(1)

(32 to 131°F)

(1)

User-supplied cabinet air cooling system must provide adequate heat dissipation to maintain
an internal temperature not to exceed 55

° C. Refer to

Table 1.A

for drive air watts loss.

Storage Temperature (Ambient):

-40

to 65°C (−40 to 149°F)

Humidity:

5% to 95% (non-condensing)