Speed command file, Speed command file -10 – Rockwell Automation 20M LPM15 Liquid-Cooled Adjustable Frequency AC Drive FRN 2.xxx User Manual

Page 58

Advertising
background image

3-10

Programming and Parameters

Speed Command File

Fil

e

Gr

oup

No.

Parameter Name & Description

See

page 3-2

for symbol descriptions

Values

Related

SPEED

COMMAND

Spd Mode

&

Limits

080

[Speed Mode]

Sets the method of speed regulation.

Default:

Options:

0

0
1
2

“Open Loop”

“Open Loop”
“Slip Comp”
“Process PI”

124

thru

138

081

[Minimum Speed]

Sets the low limit for speed reference after scaling is applied. Refer to
parameter 083 [Overspeed Limit].

Default:

Min/Max:
Units:

0.0

0.0/[Maximum Speed]
0.1 Hz

083

,

092

,

095

082

[Maximum Speed]

Sets the high limit for speed reference after scaling is applied. Refer to
parameter 083 [Overspeed Limit].

Default:

Min/Max:
Units:

50.0 or 60.0 Hz (volt class)
[Motor NP RPM]

5.0/400.0 Hz
0.1 Hz

055

,

083

,

091

,

094

,

202

083

[Overspeed Limit]

Sets the incremental amount of the output frequency (above [Maximum
Speed]) allowable for functions such as slip compensation.

[Maximum Speed] + [Overspeed Limit] must be < [Maximum Freq]

Default:

Min/Max:
Units:

10.0 Hz

0.0/20.0 Hz
0.1 Hz

055

,

082

084
085
086

[Skip Frequency 1]
[Skip Frequency 2]
[Skip Frequency 3]

Sets a frequency at which the drive will not operate. [Skip Frequency 1-3]
and [Skip Frequency Band] must not equal 0.

Default:
Default:
Default:

Min/Max:
Units:

0.0 Hz
0.0 Hz
0.0 Hz

–/+[Maximum Speed]
0.1 Hz

087

087

[Skip Freq Band]

Determines the bandwidth around a skip frequency. [Skip Freq Band] is
split, applying 1/2 above and 1/2 below the actual skip frequency. The
same bandwidth applies to all skip frequencies.

Default:

Min/Max:
Units:

0.0 Hz

0.0/30.0 Hz
0.1 Hz

084

,

085

,

086

Allowable Output Frequency Range

Bus Regulation or Current Limit

V

olta

g

e

Frequency

Allowable Output Frequency Range

Normal Operation

Allowable Reference Frequency Range

Frequency Trim due to
Speed Control Mode

Max Volts

Motor Volts

Break Volts

Start Boost

Run

0

Min

Speed

Motor

Hz

Max

Speed

Output

Freq Limit

Max
Freq

Break

Frequency

Overspeed

Limit