Programming and Parameters

3-15

Dynamic Control File

Fil

e

Gr

oup

No.

Parameter Name & Description

See

page 3-2

for symbol descriptions

Values

Related

D

Y

NAMIC CO

NTR

O

L

Ramp Rates

140
141

[Accel Time 1]
[Accel Time 2]

Sets the rate of accel for all speed increases.

Default:

Min/Max:
Units:

10.0 Secs
10.0 Secs

0.1/3600.0 Secs
0.1 Secs

142

,

143

,

146

,

361

142
143

[Decel Time 1]
[Decel Time 2]

Sets the rate of decel for all speed decreases.

Default:

Min/Max:
Units:

10.0 Secs
10.0 Secs

0.1/3600.0 Secs
0.1 Secs

140

,

141

,

146

,

361

146

[S Curve %]

Sets the percentage of accel or decel time that is applied to the ramp as
S Curve. Time is added, 1/2 at the beginning and 1/2 at the end of the
ramp.

Default:

Min/Max:
Units:

0%

0/100%
1%

140

thru

143

Loa

d Limits

147

[Current Lmt Sel]

Selects the source for the adjustment of current limit (i.e. parameter,
analog input, etc.).

Default:

Options:

0

0
1
2

“Cur Lim Val”

“Cur Lim Val”
“Analog In 1”
“Analog In 2”

146

,

149

148

[Current Lmt Val]

Defines the current limit value when [Current Lmt Sel] = “Cur Lim Val.”

Default:

Min/Max:
Units:

[Rated Amps]

× 1.5

(Equation yields approximate default
value.)

Based on Drive Rating
0.1 Amps

147

,

149

149

[Current Lmt Gain]

Sets the responsiveness of the current limit.

Default:

Min/Max:
Units:

250

0/5000
1

147

,

148

150

[Drive OL Mode]

Selects the drive’s response to increasing drive temperature.

Default:

Options:

3

0
1
2
3

“Both–PWM 1st”

“Disabled”
“Reduce CLim”
“Reduce PWM”
“Both–PWM 1st”

219

151

[PWM Frequency]

Sets the carrier frequency for the PWM output.

Default:

Min/Max:
Units:

4 kHz

2/4 kHz
1 kHz

Stop/Bra

ke Modes

155
156

[Stop Mode A]
[Stop Mode B]

Active stop mode. [Stop Mode A] is active unless [Stop Mode B] is
selected by inputs.

(1)

When using options 1 or 2, read this Attention statement.

Default:
Default:

Options:

1
0

0
1
2
3

“Ramp”
“Coast”

“Coast”
“Ramp”

(1)

“Ramp to Hold”

(1)

“DC Brake”

157

,

158

,

159

157

[DC Brake Lvl Sel]

Not available.

158

[DC Brake Level]

Not available.

159

[DC Brake Time]

Not available.

160

[Bus Reg Ki]

Sets the responsiveness of the bus regulator.

Default:

Min/Max:
Units:

450

0/5000
1

161

,

162

Max Speed

Accel Time

Accel Rate

=

Max Speed
Decel Time

Decel Rate

=

!

ATTENTION: If a hazard of injury due to movement of equipment or material exists, an auxiliary
mechanical braking device must be used.