Table 4.B Fault Cross Reference – by Number

Clearing Alarms

Alarms are automatically cleared when the condition that caused the alarm
is no longer present.

Alarm Descriptions

No.

(1)

(1)

Fault numbers not listed are reserved for future use.

Fault

No.

(1)

Fault

No.

(1)

Fault

2

Auxiliary Input

41

Phase UV Short

81- 85

Port 1-5 DPI Loss

3

Power Loss

42

Phase VW Short

87

IXo VoltageRange

4

UnderVoltage

43

Phase UW Short

88

Software Fault

5

OverVoltage

48

Params Defaulted

89

Software Fault

7

Motor Overload

49

Drive Powerup

93

Hardware Fault

8

Heatsink OvrTemp

51

Flt QueueCleared

100

Parameter Chksum

9

Trnsistr OvrTemp

52

Faults Cleared

101-103 UserSet Chksum

12

HW OverCurrent

55

Cntl Bd Overtemp

104

Pwr Brd Chksum1

13

Ground Fault

63

Shear Pin

105

Pwr Brd Chksum2

24

Decel Inhibit

64

Drive OverLoad

106

Incompat MCB-PB

25

OverSpeed Limit

68

Gate Kill

107

Replaced MCB-PB

29

Analog In Loss

69

DB Resistance

108

Anlg Cal Chksum

33

Auto Rstrt Tries

71- 75 Port 1-5 Adapter

120

I/O Mismatch

36

SW OverCurrent

77

IR Volts Range

121

I/O Comm Loss

38

Phase U to Grnd

78

FluxAmpsRef Rang

122

I/O Failure

39

Phase V to Grnd

79

Excessive Load

130

Hardware Fault

40

Phase W to Grnd

80

AutoTune Aborted

131

Hardware Fault

Table 4.C Alarm Descriptions and Actions

Alarm

No. Type

(1)

Description

Analog In Loss

5

An analog input is configured for “Alarm” on signal loss and signal
loss has occurred.

Bipolar Conflict

20

Parameter 190 [Direction Mode] is set to “Bipolar” or “Reverse Dis”
and one or more of the following digital input functions is configured:

“Fwd/Reverse,” “Run Forward,” “Run Reverse,” “Jog Forward” or
“Jog Reverse.”

Decel Inhibt

10

Drive is being inhibited from decelerating.

Dig In ConflictA

17

Digital input functions are in conflict. Combinations marked with a
“ ” will cause an alarm.

Acc2/Dec2

Accel 2 Decel 2 Jog

Jog

Fwd

Jog

Rev

Fwd/

Rev

Acc2 / Dec2

Accel 2

Decel 2

Jog*

Jog Fwd

Jog Rev

Fwd/Rev