How parameters are organized, File-group-parameter order, How parameters are organized -2 – Rockwell Automation 20M LPM15 Liquid-Cooled Adjustable Frequency AC Drive FRN 2.xxx User Manual

Page 50

Advertising
background image

3-2

Programming and Parameters

How Parameters are
Organized

The LCD HIM displays parameters in a File-Group-Parameter or Numbered
List
view order. To switch display mode, access the Main Menu, press ALT,
then Sel while cursor is on the parameter selection. In addition to using

[Param Access Lvl]

, the user has the option to display all parameters,

commonly used parameters, or diagnostic parameters.

File-Group-Parameter Order

This simplifies programming by grouping parameters that are used for
similar functions. The parameters are organized into 6 files in Basic
Parameter view or 7 files in Advanced Parameter view. Each file is divided
into groups, and each parameter is an element in a group. By default, the
LCD HIM displays parameters by File-Group-Parameter view.

No.

Description

File – Lists the major parameter file category.

Group – Lists the parameter group within a file.

No. – Parameter number.

= Parameter value cannot be changed until drive is stopped.

= 32 bit parameter in the Standard Control option.

Parameter Name & Description – Parameter name as it appears on an LCD HIM, with a brief
description of the parameters function.

Values – Defines the various operating characteristics of the parameter. Three types exist.
ENUM

Default:
Options:

Lists the value assigned at the factory. “Read Only” = no default.
Displays the programming selections available.

Bit

Bit:

Lists the bit place holder and definition for each bit.

Numeric Default:

Min/Max:
Units:

Lists the value assigned at the factory. “Read Only” = no default.
The range (lowest and highest setting) possible for the parameter.
Unit of measure and resolution as shown on the LCD HIM.

Important: Some parameters will have two unit values. Analog inputs can be set for
current or voltage with [Anlg In Config], parameter 320.
Important: When sending values through DPI ports, simply remove the decimal
point to arrive at the correct value (i.e. to send “5.00 Hz,” use “500”).

Related – Lists parameters (if any) that interact with the selected parameter. The symbol “

indicates that additional parameter information is available in

Appendix D

.

Fil

e

Gr

oup

No.

Parameter Name & Description

Values

Related

UTILIT

Y

Drive

. . .

198 Load Frm Usr Set]

Loads a previously saved set of parameter
values from a selected user set location in
drive nonvolatile memory to active drive
memory.

Default:

Options:

0

0
1
2
3

“Ready”

“Ready”
“User Set 1”
“User Set 2”
“User Set 3”

199

Diagnostics

216 [Dig In Status]

Status of the digital
inputs.

0

0

0

0

0

0

x

x

x

x

x

x

x

x

x

x

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 =Input Present
0 =Input Not Present
x =Reserved

Bit #

Digital In1

Digital In2

Digital In3

Digital In4

Digital In5

Digital In6

➊ ➌

32