Rockwell Automation 20M LPM15 Liquid-Cooled Adjustable Frequency AC Drive FRN 2.xxx User Manual

Page 68

Advertising
background image

3-20

Programming and Parameters

UTILI

T

Y

Dr

iv

e Me

mor

y

200

[Reset Meters]

Resets selected meters to zero.

Default:

Options:

0

0
1
2

“Ready”

“Ready”
“MWh”
“Elapsed Time”

201

[Language]

Selects the display language when using an LCD HIM. This parameter is
not functional with an LED HIM.
Options 6, 8, and 9 are “Reserved.”

Default:

Options:

0

0
1
2
3
4
5
7
10

“Not Selected”

“Not Selected”
“English”
“Francais”
“Español”
“Italiano”
“Deutsch”
“Português”
“Nederlands”

202

[Voltage Class]

Configures the drive current rating and associates it with the selected
voltage (i.e. 400 or 480V). Normally used when downloading parameter
sets. Options 2 and 3 indicate status only.

Default:

Options:

2
3

Based on Drive Cat. No.

“Low Voltage”
“High Voltage”

041

thru

047

054

,

055

,

062

,

063

,

069

thru

072

082

,

148

,

158

203

[Drive Checksum]

Provides a checksum value that indicates whether or not a change in
drive programming has occurred.

Default:

Min/Max:
Units:

Read Only

0/65535
1

Diagnostics

209

[Drive Status 1]

Present operating condition of the drive.

Read Only

210

210

[Drive Status 2]

Present operating condition of the drive.

Read Only

209

Fil

e

Gr

oup

No.

Parameter Name & Description

See

page 3-2

for symbol descriptions

Values

Related

0

1

1

0

0

0

0

0

0

1

1

1

0

0

0

0

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 =Condition True
0 =Condition False
x =Reserved

Bit #

Read

y

Active

Command Dir

Actual Dir

Accelerating

Decelerating

Alarm

Faulted

At Speed

Local ID 0

(1)

Local ID 1

(1)

Local ID 2

(1)

Spd Ref ID 0

(2)

Spd Ref ID 1

(2)

Spd Ref ID 2

(2)

Spd Ref ID 3

(2)

Bits

(2)

Description

Bits

(1)

Description

15 14 13 12

11 10 9

0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1

0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1

0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1

0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1

Ref A Auto
Ref B Auto
Preset 2 Auto
Preset 3 Auto
Preset 4 Auto
Preset 5 Auto
Preset 6 Auto
Preset 7 Auto
TB Manual
Port 1 Manual
Port 2 Manual
Port 3 Manual
Port 4 Manual
Port 5 Manual
Port 6 Manual
Jog Ref

0
0
0
0
1
1
1
1

0
0
1
1
0
0
1
1

0
1
0
1
0
1
0
1

Port 0 (TB)
Port 1
Port 2
Port 3
Port 4
Port 5
Port 6
No Local Control

0

0

0

0

0

0

0

x

0

0

0

0

0

0

x

x

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 =Condition True
0 =Condition False
x =Reserved

Bit #

Read

y

Active

Running

Jog

ging

Stopping

DC Braking

A

utoT

uning

A

utoRst Ctdn

A

utoRst Act

Curr Limit

Bus Freq Reg

Motor Overld

DPI at 500 k

Advertising