Using Explicit Messaging

6-15

Figure 6.8 Example SLC Ladder Logic Program

For the I/O message portion of this ladder example program, see

Figure 5.6

.

Explicit Messaging Example

When B3:2/0 is set ON, this rung will copy the 32 words of Explicit Message from
the buffer at N9:10 to the M0 File Explicit Message buffer. The scanner will send
the message out over DeviceNet.

0014

B3:2

0

COP

Copy File
Source

#N9:10

Dest

#M0:1.224

Length

32

COP

U

B3:2

0

When I:1.0/15 is ON (response to the explicit message is available), the response
message is copied into N9:50. A "4" command is copied into the M0 file, which
commands the 1747-SDN to discard the response data so that the buffer can be used
for the next message.

0015

I:1

15

1747-SDN

COP

Copy File
Source

#M1:1.224

Dest

#N9:50

Length

32

COP

EQU

Equal
Source A

N9:10

257<
Source B

N9:50

257<

EQU

MVM

Masked Move
Source

N9:0

4<
Mask

00FFh

255<
Dest

M0:1.224

?<

MVM

0016

END