Feedback and I/O

Drive Status Conditions

For PowerFlex 750-Series drives utilizing an option module, the table below
shows an overview of the selectable configurations for the drive’s digital output
Sel parameters.

Refer the PowerFlex 750-Series Programming Manual, publication

750-PM001

,

for specific parameter bit level details.

Parameter No.

Parameter Name

Description

220

(1)

(1) PowerFlex 753 drives only.

Digital In Sts

Status of the digital inputs resident on the main control board (Port 0).

227

(1)

Dig Out Setpoint

Controls Relay or Transistor Outputs when chosen as the source. Can be
used to control outputs from a communication device using DataLinks.

233

(1)

RO0 Level CmpSts

Status of the level compare, and a possible source for a relay or transistor
output.

720

PTP PsnRefStatus

Displays the current operating status of the Point-To-Point Position
Planner in the Position Referencing.

724

Psn Reg Status

Indicates status of position control logic.

730

Homing Status

Indicates status of position control logic.

933

Start Inhibits

Indicates which condition is preventing the drive from starting or running.

935

Drive Status 1

Present operating condition of the drive.

936

Drive Status 2

Present operating condition of the drive.

937

Condition Sts 1

Status of conditions that can result in the drive taking action (faulting),
based on configuration of protective functions.

945

At Limit Status

Status of dynamic conditions within the drive that are either active or a
limit is being applied.

952

Fault Status A

Indicates the occurrence of conditions that have been configured as faults.
These conditions are from P937 [Condition Sts 1].

953

Fault Status B

Indicates the occurrence of conditions that have been configured as faults.

959

Alarm Status A

Indicates the occurrence of conditions that have been configured as
alarms. These events are from P937 [Condition Sts 1].

960

Alarm Status B

Indicates the occurrence of conditions that have been configured as
alarms.

961

Type 2 Alarms

Indicates the occurrence of conditions that have been configured as
alarms.

1089

PID Status

Status of the Process PI regulator.

1103

(2)

(2) PowerFlex 755 drives only.

Trq Prove Status

Displays the status bits for TorqProve.

1210

(2)

Profile Status

Indicates status of speed profile/position indexer control logic.

1

(3)(4)

(3) Option modules can be used in Ports 4, 5, and 6 of PowerFlex 753 drives.
(4) Option modules can be used in Ports 4, 5, 6, 7, and 8 of PowerFlex 755 drives.

Dig In Sts

Status of the digital inputs.

7

(3)(4)

Dig Out Setpoint

Controls Relay or Transistor Outputs when chosen as the source. Can be
used to control outputs from a communication device using DataLinks.

13

(3)(4)

RO0 Level CmpSts

Status of the level compare, and a possible source for a relay or transistor
output.

50

(5)

(5) Port 14: DeviceLogix software parameters.

DLX DigOut Sts

Provides the individual on/off status of the DLX Logic Command word bits.

51

(5)

DLX DigOut Sts2

Provides the individual on/off status of the 16 DLX DOPs.