Rockwell Automation Publication 750-RM002B-EN-P - September 2013

43

Drive Configuration

Chapter 1

Operation

Bus voltage regulation begins when the bus voltage exceeds the bus voltage
regulation setpoint V

reg

and the switches shown in

Figure 1

move to the positions

shown.

Figure 1 - Bus Voltage Regulator, Current Limit, and Frequency Ramp

SW 1

SW 2

SW 3

SW 4

SW 5

Bus Regulation

Limit

Bus Reg

Open

Closed

Don’t Care

Current Limit

Derivative Gain

Block

Magnitude

Calculator

PI Gain Block

Current Limit Level

U Phase Motor Current

W Phase Motor Current

SW 3

I Limit,

No Bus Reg

Pr

opor

tional

Cha

nne

l

In

te

gr

al Ch

ann

el

0

Acc/Dec Rate

Jerk

Ramp

Jerk

Clamp

No Limit

SW 2

I Limit,

No Bus Reg

Bus Reg

Frequency

Ramp

(Integrator)

Output Frequency

Frequency

Limits

Frequency

Reference

SW 5

Speed

Control

Mode

Frequency Setpoint

Maximum Frequency, Minimum Speed, Maximum Speed, Overspeed Limit

Frequency Reference (to Ramp Control, Speed Ref, and so forth.)

Speed Control (Slip Comp, Process PI, and so forth.)

Bus Voltage Regulation Point, V

reg

Bus Voltage Regulator

Bus Voltage (V

bus

)

In

te

gr

al

C

hannel

Pr

op

or

tion

al

C

ha

nne

l

SW 4

Bus Reg On

Derivative

Gain Block

PI Gain Block

Limit

No Limit

SW 1

Advertising