Rockwell Automation 20G PowerFlex 750-Series AC Drives User Manual
Page 310
Advertising

310
Rockwell Automation Publication 750-RM002B-EN-P - September 2013
Chapter 6
Integrated Motion on the EtherNet/IP Network Applications for PowerFlex 755 AC Drives
2.
Open the PowerFlex 755 drive module and click the Associated Axis tab.
3.
From the Axis 1 pull-down menu, choose the feedback axis you created
(Dual_Loop_Axis in this example).
4.
From the Motor/Master Feedback Device pull-down menu, choose Port 5
Channel A.
5.
From the Load Feedback Device pull-down menu, choose Port 4 Channel
A.
6.
Click OK.