Real Time Clock

The PowerFlex 755 is equipped with a real-time clock with a battery backup.
This enables programming of real time in the drive, and keeping that time even if
the drives power is removed. This enables actual timestamps instead of runtime
timestamps for faults and events. It is also used in the runtime accumulation of
maintenance items such as total run time, number of times fans are running and
so forth. If a battery is installed and the time values are set, time is accumulated.
Approximate battery life is 4.5 years with drive unpowered, or lifetime if drive is
powered.

The real time clock on the drive can be set two different ways. It can either be set
from the HIM, or from Drive Executive/Drive Explorer.

Setting the Real Time Clock via Drive HIM

1.

Access the Status screen.

2.

If Port 00 (Host Drive) is not shown above the ESC soft key, use the

or

key to scroll to Port 00.

3.

Press the

key to display its last-viewed folder.

4.

Use the

or

key to scroll to PROPERTIES folder.

5.

Use the

or

key to select Set Date and Time.

6.

Press the

(Enter) key to display its last-viewed folder.

7.

Press the EDIT soft key to access the Set Date and Time mode screen,
which highlights the present time zone line.

8.

To select the time zone (set the drive to the current time zone).

Press the ZONES soft key to display the Select Time Zone screen.

Use the

or

key to select your basic time zone region (for

example, Full List).

Press the

(Enter) key to enter your selection.

Use the

or

key to select your specific time zone (for

example, Chicago), and press the

(Enter) key to enter it.

9.

To set the date (set the drive to the current date).

Press the

soft key to select the year in the top line, and use the

numeric keys to enter the correct year.

To delete an erroneous date (or time) entry, use the ← soft key. Also, a
partial or complete date (or time) value will not update until you press the

soft key to enter the data. You have to press the ? soft key a second time