Ring/star topology – Rockwell Automation 20G PowerFlex 750-Series AC Drives User Manual

Page 345

Advertising
background image

Rockwell Automation Publication 750-RM002B-EN-P - September 2013

345

Integrated Motion on the EtherNet/IP Network Applications for PowerFlex 755 AC Drives

Chapter 6

Ring/Star Topology

Network switches can also be connected into a DLR via an Ethernet/IP tap,
creating a ring/star topology.

It is recommended that a managed switch with a transparent and/or boundary
clock, plus QoS and IGMP protocol support be used for this Network topology.

Although the ControlLogix controller is illustrated, the CompactLogix
controller could also be used.

PowerFlex 755 and Kinetix
7000 Drive Overload Rating
Comparison for Permanent
Magnet Motor Operation

The PowerFlex 755 drive can be configured for a normal duty or heavy duty
operation. The heavy duty rating has a lower continuous current rating and
therefore can produce more current during an overload.

The Kinetix 7000 drive overload capability is specific for each power structure.
However, the Kinetix 7000 can produce 100% current at 0 Hz.

With permanent magnet motors, the torque is directly proportional to the
current. Therefore, the overload ratings of the drive to which the motor is
connected provides the torque overload capability of the motor.

PowerFlex 755

PowerFlex 755

PowerFlex 755

PowerFlex 755

PowerFlex 755

1756-EN2T

or

1756-ENxTR

1585J-M8CBJM-x
EtherNet (shielded) Cable

Programming Software

Other EtherNet/IP

Compatible Devices

1783-ETAP

Stratix 8000

Duty Rating

0 Hz

100%

110%

150%

180%

Normal

50%

100%

One minute

3 seconds

Not applicable

Heavy

65%

75% of normal

duty

One minute of

normal duty

3 seconds of
normal duty

Advertising