Appendix a, Appendix – Rockwell Automation 20G PowerFlex 750-Series AC Drives User Manual

Page 419

Advertising
background image

Rockwell Automation Publication 750-RM002B-EN-P - September 2013

419

Appendix

A

PowerFlex 755 Standard and Safety Drive Module Optional Attributes

The following table specifies what optional attribute and corresponding control
mode functionality is supported by a PowerFlex 755 drive module when using
the Logix Designer application.

Y = The attribute/enum/bit is supported

N = The attribute/enum/bit is not supported

R = The attribute is required

Control Modes

N = No Control Mode

F = Frequency Control Mode

P = Position Control Mode

V = Velocity Control Mode

T = Torque Control Mode

For more information on the Control Modes, see Integrated Motion on the
Ethernet/IP Network Reference Manual, publication

MOTION-RM003

.

The Integrated Motion on the Ethernet/IP Network Reference Manual provides
a programmer with details about the Integrated Motion on the Ethernet/IP
Network Control Modes, Control Methods, and AXIS_CIP_DRIVE
Attributes.

Table 29 - Conditional Implementation Key

Key

Description

AOP

Special device specific semantics needed from AOP

Co

Controller only attribute (controller attribute that resides only in controller)

C/D

Yes = The attribute is replicated in the drive

CScale

Motion Scaling Configuration set to Controller Scaling

Derived

Implementation rules follow another attribute

Dr

Drive replicated attribute (controller attribute that is replicated in drive)

Drive Scaling

Drive device supports drive scaling functionality

DScale

Motion Scaling Configuration set to Drive Scaling

E21

EnDat 2.1® (feedback type)

E22

EnDat 2.2® (feedback type)

E

Encoder-based control, a feedback device is present

!E

Encoderless or sensorless control, a feedback device in not present

HI

Hiperface® (feedback type)

Advertising
This manual is related to the following products: