Motor Control
Chapter 4
and the RED line depicts the drive’s commanded speed reference (actual). Notice
there are different results, depicted by the grey dotted line, along the graph.
Maximum Frequency
P37 [Maximum Freq] defines the maximum reference frequency. The actual
output frequency can be greater as a result of slip compensation and other types
of regulation.
2 [Commanded SpdRef]
546 [Spd Ref A Stpt]
522 [Min Fwd Speed]
521 [Max Rev Speed]
523 [Min Rev Speed]
520 [Max Fwd Speed]